Mylar® 30PCR1 is a film produced using nominal 30% Post Consumer Recycle (PCR) material. It is chemically treated on one side for ink adhesion. Film is used for a variety of industrial applications.
|
Available Thickness [Gauge] |
48; 92
|
|
|
Property |
Thickness |
Value |
Units |
Test |
OPTICAL
|
Haze |
48 |
3 |
% |
ASTM D1003 |
Haze |
92 |
4 |
% |
ASTM D1003 |
|
PHYSICAL
|
Elongation at Break MD |
48 |
130 |
% |
ASTM D882A |
Elongation at Break MD |
92 |
135 |
% |
ASTM D882A |
Elongation at Break TD |
48 |
100 |
% |
ASTM D882A |
Elongation at Break TD |
92 |
105 |
% |
ASTM D882A |
Tensile Modulus MD |
48 |
500,000 |
psi |
ASTM D882A |
Tensile Modulus MD |
92 |
500,000 |
psi |
ASTM D882A |
Tensile Modulus TD |
48 |
530,000 |
psi |
ASTM D882A |
Tensile Modulus TD |
92 |
540,000 |
psi |
ASTM D882A |
Tensile Strength MD |
48 |
25 |
kpsi |
ASTM D882A |
Tensile Strength MD |
92 |
25 |
kpsi |
ASTM D882A |
Tensile Strength TD |
48 |
30 |
kpsi |
ASTM D882A |
Tensile Strength TD |
92 |
30 |
kpsi |
ASTM D882A |
|
THERMAL
|
Shrinkage MD (150℃) |
48 |
1.5 |
% |
Unrestrained @ 150℃/30 min |
Shrinkage MD (150℃) |
92 |
1.0 |
% |
Unrestrained @ 150℃/30 min |
Shrinkage TD (150℃) |
48 |
0.5 |
% |
Unrestrained @ 150℃/30 min |
Shrinkage TD (150℃) |
92 |
0.1 |
% |
Unrestrained @ 150℃/30 min |
|
|
Mylar® Specialty Films U.S. Limited Partnership
3600 Discovery Drive
Chester, VA 23836-6436 USA
Tel: (800) 635-4639
Fax: (804) 530-9867
|
Note: These values are typical performance data for Mylar® Specialty Films' polyester film; they are not intended to be used as design data. We believe this information is the best currently available on the subject. It is offered as a possible helpful suggestion in experimentation you may care to undertake along these lines. It is subject to revision as additional knowledge and experience is gained. Mylar® Specialty Films makes no guarantee of results and assumes no obligation or liability whatsoever in connection with this information. This publication is not a license to operate under, or intended to suggest infringement of, any existing patents.
CAUTION: Do not use in medical applications involving permanent implantation in the human body (Mylar® Specialty Films Medical Policy). For other medical applications, see the Medical Caution Statement. Mylar® Specialty Films accepts no liability for use of it's products in medical applications not reviewed and approved by Mylar® Specialty Films or for product misuse. Mylar® Specialty Films supplies products to an agreed specification and does not manufacture products designed specifically for medical end use.
Melinex®, Mylar® and Melinex® STTM are registered trademarks of Mylar® Specialty Films U.S. Limited Partnership.
|
|