Mylar® 7132 is an uncoated, transparent polyester packaging film designed with high shrinkage.
|
7132 is used in frozen food applications as well as general bag formation.
|
Food Contact Status -
Please contact your Mylar® Specialty Films representative to receive the Regulatory Compliance documents
|
Dispose of in compliance with federal, state and local regulations. Preferred options for disposal are (1) recycling, (2) incineration with energy recovery, and (3) landfill. The high fuel value of this product makes option No. 2 very desirable for material that cannot be recycled.
|
Available Thickness [Gauge] |
80
|
|
|
Property |
Thickness |
Value |
Units |
Test |
BARRIER
|
Gas Permeability - O2, 24 hr |
80 |
7 |
cc/100 in² |
ASTM D3985 22℃/75% RH/1 ATM |
WVTR |
80 |
1.9 |
g/100 in²/day |
ASTM F1249 38℃, 90% RH |
|
OPTICAL
|
Haze |
80 |
7 |
% |
ASTM D1003 |
|
PHYSICAL
|
Elongation at Break MD |
80 |
160 |
% |
ASTM D882A |
Elongation at Break TD |
80 |
130 |
% |
ASTM D882A |
Tensile Modulus MD |
80 |
350 |
kpsi |
ASTM D882A |
Tensile Modulus TD |
80 |
450 |
kpsi |
ASTM D882A |
Tensile Strength MD (break) |
80 |
25 |
kpsi |
ASTM D882A |
Tensile Strength TD (break) |
80 |
30 |
kpsi |
ASTM D882A |
Yield (nominal) |
80 |
24800 |
in²/lb |
|
|
THERMAL
|
Shrinkage MD (Boiling Water) |
80 |
28 |
% |
Boiling Water - 30 seconds |
Shrinkage TD (Boiling Water) |
80 |
32 |
% |
Boiling Water - 30 seconds |
|
|
Mylar® Specialty Films U.S. Limited Partnership
3600 Discovery Drive
Chester, VA 23836-6436 USA
Tel: (800) 635-4639
Fax: (804) 530-9867
|
Note: These values are typical performance data for Mylar® Specialty Films' polyester film; they are not intended to be used as design data. We believe this information is the best currently available on the subject. It is offered as a possible helpful suggestion in experimentation you may care to undertake along these lines. It is subject to revision as additional knowledge and experience is gained. Mylar® Specialty Films makes no guarantee of results and assumes no obligation or liability whatsoever in connection with this information. This publication is not a license to operate under, or intended to suggest infringement of, any existing patents.
CAUTION: Do not use in medical applications involving permanent implantation in the human body (Mylar® Specialty Films Medical Policy). For other medical applications, see the Medical Caution Statement. Mylar® Specialty Films accepts no liability for use of it's products in medical applications not reviewed and approved by Mylar® Specialty Films or for product misuse. Mylar® Specialty Films supplies products to an agreed specification and does not manufacture products designed specifically for medical end use.