MYLAR® 822C

Product Description
Mylar® 822C is a polyester film that has been chemically pretreated on one side and corona treated on the other. It is designed for printing and extruded polyethylene adhesion.



Approvals
Food Contact Status - Please contact your Mylar® Specialty Films representative to receive the Regulatory Compliance documents



Typical Properties
Available Thickness [Gauge]
48;    92;    200


Property Thickness Value Units Test
BARRIER
Gas Permeability - O2, 24 hr  48  cc/100 in²  ASTM D1434 77℉/75% RH/1 ATM 
WVTR  48  2.8  g/100 in²/day  ASTM F1249 38℃, 90% RH 
 
OPTICAL
Haze  200  8.8  ASTM D1003 
Haze  48  3.8  ASTM D1003 
Haze  92  5.7  ASTM D1003 
 
PHYSICAL
C.O.F. (dynamic)  48-200  0.4    ASTM D1894 
C.O.F. (static)  48  0.5    ASTM D1894 
Density  48-200  1.40  g/cc   
Elongation at Break MD   200  150  ASTM D882A 
Elongation at Break MD  48  110  ASTM D882A 
Elongation at Break MD  92  130  ASTM D882A 
Elongation at Break TD  200  110  ASTM D882A 
Elongation at Break TD  48  70  ASTM D882A 
Elongation at Break TD  92  90  ASTM D882A 
Surface Tension (Minimum)  48-200  50  Dyne/cm  ASTM D2578  
Tensile Strength MD (break)  48-200  28,500  psi  ASTM D882A 
Tensile Strength TD (break)  200  33,000  psi  ASTM D882A 
Tensile Strength TD (break)  48 & 92  36,000  psi  ASTM D882A 
 
THERMAL
Shrinkage MD (190℃)  48-200  Unrestrained @ 190℃/5 min 
Shrinkage TD (190℃)  200  0.6  Unrestrained @ 190℃/5 min 
Shrinkage TD (190℃)  48 & 92  1.3  Unrestrained @ 190℃/5 min 



Contact Info
Mylar® Specialty Films U.S. Limited Partnership
3600 Discovery Drive
Chester, VA 23836-6436 USA
Tel: (800) 635-4639
Fax: (804) 530-9867



Disclaimer
Note: These values are typical performance data for Mylar® Specialty Films' polyester film; they are not intended to be used as design data. We believe this information is the best currently available on the subject. It is offered as a possible helpful suggestion in experimentation you may care to undertake along these lines. It is subject to revision as additional knowledge and experience is gained. Mylar® Specialty Films makes no guarantee of results and assumes no obligation or liability whatsoever in connection with this information. This publication is not a license to operate under, or intended to suggest infringement of, any existing patents.

CAUTION: Do not use in medical applications involving permanent implantation in the human body (Mylar® Specialty Films Medical Policy). For other medical applications, see the Medical Caution Statement. Mylar® Specialty Films accepts no liability for use of it's products in medical applications not reviewed and approved by Mylar® Specialty Films or for product misuse. Mylar® Specialty Films supplies products to an agreed specification and does not manufacture products designed specifically for medical end use.

Melinex®, Mylar® and Melinex® STTM are registered trademarks of Mylar® Specialty Films U.S. Limited Partnership.