MELINEX® 478

Product Description
Melinex® 478 is a high clarity polyester film manufactured with a coating on both surfaces that improves slip and handling characteristics.


Typical Applications
Melinex 478 is used in many general industrial applications where clarity and handling properties are critical, e.g., overlay, lamination and printing applications.




Typical Properties
Available Thickness [Gauge]
200;    300;    500;    700


Property Thickness Value Units Test
OPTICAL
Haze  200 - 300  0.4  ASTM D1003 
Haze  500  0.6  ASTM D1003 
Haze  700  0.8  ASTM D1003 
 
PHYSICAL
C.O.F. (dynamic) A-B  200 - 700  0.70  (Maximum)  ASTM D1894 
F5-MD  200 - 700  14,000  psi  ASTM D882A 
F5-TD  200 - 700  14,000  psi  ASTM D882A 
Tensile Strength MD  200 - 700  25,000  psi  ASTM D882A 
Tensile Strength TD  200 - 700  36,000  psi (Minimum)  ASTM D882A 
Yield (nominal)  200  9,918  in²/lb   
Yield (nominal)  300  6,612  in²/lb    
Yield (nominal)  500  4,032  in²/lb    
Yield (nominal)  700  2,875  in²/lb    
 
THERMAL
Shrinkage MD (190℃)  200 - 700  2.5  Unrestrained @ 190℃/5 min 
Shrinkage TD (190℃)  200 - 700  1.0  Unrestrained @ 190℃/5 min 



Contact Info
Mylar® Specialty Films U.S. Limited Partnership
3600 Discovery Drive
Chester, VA 23836-6436 USA
Tel: (800) 635-4639
Fax: (804) 530-9867



Disclaimer
Note: These values are typical performance data for Mylar® Specialty Films' polyester film; they are not intended to be used as design data. We believe this information is the best currently available on the subject. It is offered as a possible helpful suggestion in experimentation you may care to undertake along these lines. It is subject to revision as additional knowledge and experience is gained. Mylar® Specialty Films makes no guarantee of results and assumes no obligation or liability whatsoever in connection with this information. This publication is not a license to operate under, or intended to suggest infringement of, any existing patents.

CAUTION: Do not use in medical applications involving permanent implantation in the human body (Mylar® Specialty Films Medical Policy). For other medical applications, see the Medical Caution Statement. Mylar® Specialty Films accepts no liability for use of it's products in medical applications not reviewed and approved by Mylar® Specialty Films or for product misuse. Mylar® Specialty Films supplies products to an agreed specification and does not manufacture products designed specifically for medical end use.

Melinex®, Mylar® and Melinex® STTM are registered trademarks of Mylar® Specialty Films U.S. Limited Partnership.