Welcome, Guest Current Language:   US
  Home | Welcome Page | Film Type Selector | Market Locator | Product Locator
 

Show Printable Version  
 
MYLAR® RSX951

Product Description
Mylar® RSX951 is a silicone coated polyester film designed for use as a release liner in various casting applications. The silicone release coating is applied to the film during the film production process, providing excellent adhesion of the coating to the polyester film for improved liner performance.

General Product Info
Mylar® RSX951 has balanced tensile properties and good dimensional stability. Release values typically range between 15 and 25 grams per inch when tested with aggressive pressure-sensitive adhesives. It is recommended that the liner be tested in each application to verify the absolute value of the release strength.



Typical Properties
Available Thickness [Gauge]
92;    105;    120;    140;    175;    200


Property Thickness Value Units Test
OPTICAL
Haze  92  5.9  ASTM D1003 
Haze  105  6.3  ASTM D1003 
Haze  120  6.7  ASTM D1003 
Haze  140  7.1  ASTM D1003 
Haze  175  7.5  ASTM D1003 
Haze  200  9.8  ASTM D1003 
 
PHYSICAL
Elongation at Break MD  92, 105  130  ASTM D882A 
Elongation at Break MD  120  140  ASTM D882A 
Elongation at Break MD  140, 175  150  ASTM D882A 
Elongation at Break MD  200  150  ASTM D882A 
Elongation at Break TD  92, 105  105  ASTM D882A 
Elongation at Break TD  120  110  ASTM D882A 
Elongation at Break TD  140, 175  115  ASTM D882A 
Elongation at Break TD  200  110  ASTM D882A 
Peel Strength  All  16  g/25 mm  Using Tesa 7475 Tape 
Tensile Strength MD  All  28.0  kpsi  ASTM D882A 
Tensile Strength TD  All  34.0  kpsi  ASTM D882A 
 
THERMAL
Shrinkage MD (150℃)  92 - 200  2.3  Unrestrained @ 150℃/30 min 
Shrinkage TD (150℃)  92 - 200  0.5  Unrestrained @ 150℃/30 min 


Contact Info
Mylar® Specialty Films U.S. Limited Partnership
3600 Discovery Drive
Chester, VA 23836-6436 USA
Tel: (800) 635-4639
Fax: (804) 530-9867


Disclaimer
Note: These values are typical performance data for Mylar® Specialty Films' polyester film; they are not intended to be used as design data. We believe this information is the best currently available on the subject. It is offered as a possible helpful suggestion in experimentation you may care to undertake along these lines. It is subject to revision as additional knowledge and experience is gained. Mylar® Specialty Films makes no guarantee of results and assumes no obligation or liability whatsoever in connection with this information. This publication is not a license to operate under, or intended to suggest infringement of, any existing patents.

CAUTION: Do not use in medical applications involving permanent implantation in the human body (Mylar® Specialty Films Medical Policy). For other medical applications, see the Medical Caution Statement. Mylar® Specialty Films accepts no liability for use of it's products in medical applications not reviewed and approved by Mylar® Specialty Films or for product misuse. Mylar® Specialty Films supplies products to an agreed specification and does not manufacture products designed specifically for medical end use.

Melinex®, Mylar® and Melinex® STTM are registered trademarks of Mylar® Specialty Films U.S. Limited Partnership.
 
  Show Printable Version
 
  Copyright © 2024 Mylar® Specialty Films. All rights reserved. | Privacy
  Developed and Powered by Client Centered Technologies, Inc.