Mylar® MLB is an uncoated, transparent, polyester film designed for use as a component of a lamination structure and may be suitable for use in medical applications. Mylar® MLB is commercially available in nominal 48 and 300 gauge.
Mylar® MLB is available with corona treatment on one or both sides. These products are known as Mylar® MLBT and MLBT2 respectively and are not offered in the 300 gauge range.
|
Mylar® MLB polyester film frequently is selected as a component of a laminated structure because of its ability to contribute great strength, high temperature resistance and flavor/odor barrier. Its sparkling clarity and relative insensitivity to heat and humidity make it an ideal print carrier and outer ply of many laminated food packaging structures. Retention of properties over a temperature range from -100℉ to 300℉ permits uses requiring freezer storage temperatures followed by heating for warming, cooking or ovenable applications. The chemical resistance and barrier to acids, weak bases, greases and oils, detergents and other active ingredients make Mylar® MLB useful in containing many "hard-to-hold" food or non-food products. Mylar® MLB is not degraded by standard sterilization procedures involving steam retorts, gamma or cobalt radiation, ethylene oxide gas exposure or hydrogen peroxide immersion.
|
A basic lamination would combine plain or printed Mylar® MLB with a heat sealable ply consisting of LDPE, LLDPE, EVA, ionomer, acid copolymer, PVC or other materials using adhesive or extrusion laminating techniques. Such structures might be suitable for heat sealed pouches for frozen foods, heat-in applications, packages not requiring high oxygen barrier, some condiments and some medical device applications. If greater gas barrier is required, a layer of foil, PVdC or EVOH may be inserted between the Mylar® MLB and the sealant layer, or barrier adhesives or sealant layers may be utilized. Typical applications might include processed meats, condiments, nuts, cheese, sauces and dry mixes.
|
Food Contact Status -
Please contact your Mylar® Specialty Films representative to receive the Regulatory Compliance documents
Drug Master File -
This product is listed in our Drug Master File.
|
Dispose of in compliance with federal, state and local regulations. Preferred options for disposal are (1) recycling, (2) incineration with energy recovery and (3) landfill. The high fuel value of this product makes option No. 2 very desirable for material that cannot be recycled.
|
Available Thickness [Gauge] |
48; 300
|
|
|
Property |
Thickness |
Value |
Units |
Test |
BARRIER
|
Gas Permeability - O2, 24 hr |
48 |
9 |
cc/100 in² |
ASTM D3985 22℃/75% RH/1 ATM |
WVTR |
48 |
2.8 |
g/100 in²/day |
ASTM F1249 38℃, 90% RH |
|
OPTICAL
|
Clarity |
48 |
76 |
% |
ASTM D1746 |
Haze |
48 |
4.0 |
% |
ASTM D1003 |
Haze |
300 |
10.5 |
% |
ASTM D1003 |
|
PHYSICAL
|
Elongation at Break MD |
48 |
110 |
% |
ASTM D882A |
Elongation at Break TD |
48 |
80 |
% |
ASTM D882A |
Modulus |
48 |
550 |
kpsi |
ASTM D882 |
Tear (Graves) |
48 |
0.7 |
lb |
ASTM D1004 |
Tensile Strength MD (break) |
48 |
27 |
kpsi |
ASTM D882A |
Tensile Strength MD (break) |
300 |
23 |
kpsi |
ASTM D882A |
Tensile Strength TD (break) |
48 |
34 |
kpsi |
ASTM D882A |
Tensile Strength TD (break) |
300 |
23 |
kpsi |
ASTM D882A |
Unit Weight |
48 |
10.4 |
in²/lb |
ASTM E252 (0.5 m2) |
Yield (nominal) |
48 |
41,700 |
in²/lb |
|
|
THERMAL
|
Shrinkage MD (150℃) |
48 |
2.2 |
% |
Unrestrained @ 150℃/30 min |
Shrinkage MD (190℃) |
300 |
2.5 |
% |
Unrestrained @ 190℃/5 min |
Shrinkage TD (150℃) |
48 |
1.3 |
% |
Unrestrained @ 150℃/30 min |
Shrinkage TD (190℃) |
300 |
0.5 |
% |
Unrestrained @ 190℃/5 Min |
|
|
Mylar® Specialty Films U.S. Limited Partnership
3600 Discovery Drive
Chester, VA 23836-6436 USA
Tel: (800) 635-4639
Fax: (804) 530-9867
|
Note: These values are typical performance data for Mylar® Specialty Films' polyester film; they are not intended to be used as design data. We believe this information is the best currently available on the subject. It is offered as a possible helpful suggestion in experimentation you may care to undertake along these lines. It is subject to revision as additional knowledge and experience is gained. Mylar® Specialty Films makes no guarantee of results and assumes no obligation or liability whatsoever in connection with this information. This publication is not a license to operate under, or intended to suggest infringement of, any existing patents.
CAUTION: Do not use in medical applications involving permanent implantation in the human body (Mylar® Specialty Films Medical Policy). For other medical applications, see the Medical Caution Statement. Mylar® Specialty Films accepts no liability for use of it's products in medical applications not reviewed and approved by Mylar® Specialty Films or for product misuse. Mylar® Specialty Films supplies products to an agreed specification and does not manufacture products designed specifically for medical end use.
Melinex®, Mylar® and Melinex® STTM are registered trademarks of Mylar® Specialty Films U.S. Limited Partnership.
|
|