Welcome, Guest Current Language:   US
  Home | Welcome Page | Film Type Selector | Market Locator | Product Locator
 

Show Printable Version  
 
MELINEX® 329

Product Description
MELINEX® 329 is an opaque white, non-pretreated, polyester film with superb handling properties and a unique glossy appearance.

Typical Applications
MELINEX® 329 is used as a base for pressure sensitive labels, in security and access cards, in multiple use tickets and in general printing applications. It is also used for medical diagnostic test strips.

Approvals
UL recognized - Product has been registered with Underwriters Laboratories


Typical Properties
Available Thickness [Gauge]
92;    142;    200;    300;    380;    500;    700;    1000;    1400


Property Thickness Value Units Test
OPTICAL
Gloss 45 Degrees  92-1400  40  ASTM D1003 
Gloss 60 Degrees  92-1400  45  ASTM D1003 
Total Light Transmission (TLT)  92  23  ASTM D1003 
Total Light Transmission (TLT)  200-300  15  ASTM D1003 
Total Light Transmission (TLT)  500-700  ASTM D1003 
Total Light Transmission (TLT)  1000-1400  ASTM D1003 
Whiteness  ALL  98  ASTM E 313-79 
 
PHYSICAL
C.O.F. (dynamic) A-B  92-1400  0.3 - 0.4    ASTM D1894 
Elongation at Break MD  92-1400  115  ASTM D882A 
Elongation at Break TD  92-1400  90  ASTM D882A 
Tensile Strength MD (break)  92-1400  16,000  psi  ASTM D882A 
Tensile Strength MD 5%  92-1400  12,000  psi  ASTM D882A 
Tensile Strength TD (break)  92-1400  19,000  psi  ASTM D882A 
Tensile Strength TD 5%  92-1400  12,000  psi  ASTM D882A 
 
THERMAL
Shrinkage MD (190°C)  92  3.0  Unrestrained @ 190°C/5 min 
Shrinkage MD (190°C)  142-200  2.8  Unrestrained @ 190°C/5 min 
Shrinkage MD (190°C)  300-1400  1.5  Unrestrained @ 190°C/5 min 
Shrinkage TD (190°C)  92  2.5  Unrestrained @ 190°C/5 min 
Shrinkage TD (190°C)  142-200  1.0  Unrestrained @ 190°C/5 min 
Shrinkage TD (190°C)  300-1400  1.5  Unrestrained @ 190°C/5 min 


Contact Info
DuPont Teijin Films U.S. Limited Partnership
3600 Discovery Drive
Chester, VA 23836 USA
Tel: (800) 635-4639
Fax: (804) 530-9867


Disclaimer
Note: These values are typical performance data for DuPont Teijin Films' polyester film; they are not intended to be used as design data. We believe this information is the best currently available on the subject. It is offered as a possible helpful suggestion in experimentation you may care to undertake along these lines. It is subject to revision as additional knowledge and experience is gained. DuPont Teijin Films makes no guarantee of results and assumes no obligation or liability whatsoever in connection with this information. This publication is not a license to operate under, or intended to suggest infringement of, any existing patents.

CAUTION: Do not use in medical applications involving permanent implantation in the human body (DuPont Teijin Films Medical Policy). For other medical applications, see the Medical Caution Statement. DuPont Teijin Films accepts no liability for use of it's products in medical applications not reviewed and approved by DuPont Teijin Films or for product misuse. DuPont Teijin Films supplies products to an agreed specification and does not manufacture products designed specifically for medical end use.

Melinex®, Mylar® and Melinex® STTM are registered trademarks of DuPont Teijin Films U.S. Limited Partnership.
 