MELINEX® 329

Product Description
MELINEX® 329 is an opaque white, non-pretreated, polyester film with superb handling properties and a unique glossy appearance.


Typical Applications
MELINEX® 329 is used as a base for pressure sensitive labels, in security and access cards, in multiple use tickets and in general printing applications. It is also used for medical diagnostic test strips.


Approvals
UL recognized - Product has been registered with Underwriters Laboratories



Typical Properties
Available Thickness [Gauge]
92;    142;    200;    300;    380;    500;    700;    1000;    1400


Property Thickness Value Units Test
OPTICAL
Gloss 45 Degrees  92-1400  40  ASTM D1003 
Gloss 60 Degrees  92-1400  45  ASTM D1003 
Total Light Transmission (TLT)  92  23  ASTM D1003 
Total Light Transmission (TLT)  200-300  15  ASTM D1003 
Total Light Transmission (TLT)  500-700  ASTM D1003 
Total Light Transmission (TLT)  1000-1400  ASTM D1003 
Whiteness  ALL  98  ASTM E 313-79 
 
PHYSICAL
C.O.F. (dynamic) A-B  92-1400  0.3 - 0.4    ASTM D1894 
Elongation at Break MD  92-1400  115  ASTM D882A 
Elongation at Break TD  92-1400  90  ASTM D882A 
Tensile Strength MD (break)  92-1400  16,000  psi  ASTM D882A 
Tensile Strength MD 5%  92-1400  12,000  psi  ASTM D882A 
Tensile Strength TD (break)  92-1400  19,000  psi  ASTM D882A 
Tensile Strength TD 5%  92-1400  12,000  psi  ASTM D882A 
 
THERMAL
Shrinkage MD (190℃)  92  3.0  Unrestrained @ 190℃/5 min 
Shrinkage MD (190℃)  142-200  2.8  Unrestrained @ 190℃/5 min 
Shrinkage MD (190℃)  300-1400  1.5  Unrestrained @ 190℃/5 min 
Shrinkage TD (190℃)  92  2.5  Unrestrained @ 190℃/5 min 
Shrinkage TD (190℃)  142-200  1.0  Unrestrained @ 190℃/5 min 
Shrinkage TD (190℃)  300-1400  1.5  Unrestrained @ 190℃/5 min 



Contact Info
Mylar® Specialty Films U.S. Limited Partnership
3600 Discovery Drive
Chester, VA 23836-6436 USA
Tel: (800) 635-4639
Fax: (804) 530-9867



Disclaimer
Note: These values are typical performance data for Mylar® Specialty Films' polyester film; they are not intended to be used as design data. We believe this information is the best currently available on the subject. It is offered as a possible helpful suggestion in experimentation you may care to undertake along these lines. It is subject to revision as additional knowledge and experience is gained. Mylar® Specialty Films makes no guarantee of results and assumes no obligation or liability whatsoever in connection with this information. This publication is not a license to operate under, or intended to suggest infringement of, any existing patents.

CAUTION: Do not use in medical applications involving permanent implantation in the human body (Mylar® Specialty Films Medical Policy). For other medical applications, see the Medical Caution Statement. Mylar® Specialty Films accepts no liability for use of it's products in medical applications not reviewed and approved by Mylar® Specialty Films or for product misuse. Mylar® Specialty Films supplies products to an agreed specification and does not manufacture products designed specifically for medical end use.

Melinex®, Mylar® and Melinex® STTM are registered trademarks of Mylar® Specialty Films U.S. Limited Partnership.