|
Mylar® RL33 is a biaxially oriented polyester (OPET) film with an ethylene vinyl acetate (EVA) heat seal layer. It is used as a heat sealable lidding film in packaging frozen and refrigerated foods. Mylar® RL33 can withstand freezing temperatures down to -40℉.
|
Mylar® RL33 is designed to seal to a broad range of container substrates including amorphous polyester (APET, also PETG), semicrystalline polyester (CPET), polyester coated paperboard, polyvinylchloride (PVC), polyethylene (HDPE), polypropylene (PP), and polystryrene (HIPS).
|
Mylar® RL33 has the same type heat seal layer as Mylar® RL31, but the seal layer is thicker than both Mylar® RL31 and Mylar® RL32. Mylar® RL33 develops stronger seals than Mylar® RL32 to most substrates and tends to produce tearing seals to non-polar substrates under chilled conditions. Mylar® RL33 is recommended when light caulking is needed. Mylar® RL33 has a lower seal initiation temperature than lidding films with an amorphous polyester heat seal layer (e.g., Mylar® OL, OL2). This allows good seals to be made at higher line speeds (or using lower sealing temperatures).
|
Corona Treatment (Mylar® RL33T): Selected gauges of Mylar® RL33 are available with corona treatment (on the opposite side of film from the heat seal layer) to enhance printing and laminating. This film type is marketed by Mylar® Specialty Films as Mylar® RL33T. The film is treated to an initial dyne level of 54. The dyne level of treated lidding films may decline with storage, and in-line corona treatment may be required during subsequent printing or laminating to increase the dyne level to a value adequate to get desired ink or laminate adhesion.
|
Anti-fog: Mylar® RL33 is not available with anti-fog capability.
|
Food Contact Status -
Please contact your Mylar® Specialty Films representative to receive the Regulatory Compliance documents
|
Disposal of Mylar® RL33 does not present special disposal problems. It can be buried as a relatively inert material in a landfill or burned in an incinerator with normal refuse. The incinerator should have sufficient draft to exhaust all combustion products through the stack to avoid exposure to irritating fumes. The disposal method should comply with local, state and federal regulations.
|
Available Thickness [Gauge] |
50; 75; 100
|
|
|
Property |
Thickness |
Value |
Units |
Test |
BARRIER
|
Gas Permeability - O2, 24 hr |
100 |
5 |
cc/100 in² |
ASTM D3985 22℃/50% RH/1 ATM |
Gas Permeability - O2, 24 hr |
50 |
9 |
cc/100 in² |
ASTM D3985 22℃/50% RH/1 ATM |
Gas Permeability - O2, 24 hr |
75 |
7 |
cc/100 in² |
ASTM D3985 22℃/50% RH/1 ATM |
WVTR |
100 |
1.3 |
g/100 in²/day |
ASTM F1249 38℃, 90% RH |
WVTR |
50 |
2.8 |
g/100 in²/day |
ASTM F1249 38℃, 90% RH |
WVTR |
75 |
1.9 |
g/100 in²/day |
ASTM F1249 38℃, 90% RH |
|
PHYSICAL
|
Elongation at Break MD |
All |
110 |
% |
ASTM D882A |
Elongation at Break TD |
All |
80 |
% |
ASTM D882A |
Modulus |
All |
550 |
kpsi |
ASTM D822 |
Tensile Strength MD (break) |
All |
25 |
kpsi |
ASTM D882A |
Tensile Strength TD (break) |
All |
35 |
kpsi |
ASTM D882A |
Unit Weight |
100 |
26.4 |
lb/ream |
ASTM E252 (0.5 m2) |
Unit Weight |
50 |
16.9 |
lb/ream |
ASTM E252 (0.5 m2) |
Unit Weight |
75 |
22.7 |
lb/ream |
ASTM E252 (0.5 m2) |
Yield (nominal) |
100 |
16,500 |
in²/lb |
|
Yield (nominal) |
50 |
26,000 |
in²/lb |
|
Yield (nominal) |
75 |
19,000 |
in²/lb |
|
|
|
Mylar® Specialty Films U.S. Limited Partnership
3600 Discovery Drive
Chester, VA 23836-6436 USA
Tel: (800) 635-4639
Fax: (804) 530-9867
|
Note: These values are typical performance data for Mylar® Specialty Films' polyester film; they are not intended to be used as design data. We believe this information is the best currently available on the subject. It is offered as a possible helpful suggestion in experimentation you may care to undertake along these lines. It is subject to revision as additional knowledge and experience is gained. Mylar® Specialty Films makes no guarantee of results and assumes no obligation or liability whatsoever in connection with this information. This publication is not a license to operate under, or intended to suggest infringement of, any existing patents.
CAUTION: Do not use in medical applications involving permanent implantation in the human body (Mylar® Specialty Films Medical Policy). For other medical applications, see the Medical Caution Statement. Mylar® Specialty Films accepts no liability for use of it's products in medical applications not reviewed and approved by Mylar® Specialty Films or for product misuse. Mylar® Specialty Films supplies products to an agreed specification and does not manufacture products designed specifically for medical end use.
Melinex®, Mylar® and Melinex® STTM are registered trademarks of Mylar® Specialty Films U.S. Limited Partnership.
|
|