MYLAR® RL32

Product Description
Mylar® RL32 is a biaxially oriented polyester (OPET) film with an ethylene vinyl acetate (EVA) heat seal layer. it is used as a heat sealable lidding film in packaging frozen and refrigerated foods. Mylar® RL32 is commercially available in nominal 50, 75, 100 and 150 gauges.

Mylar® RL32 is designed to seal to a broad range of container substrates including amorphous polyester (APET, also PETG), semicrystalline polyester (CPET), polyester coated paperboard, polyvinylchloride (PVC), polyethylene (HDPE), polypropylene (PP), and polystryrene (HIPS).


Mylar® RL32 has the same type heat seal layer as Mylar® RL31, but the thickness of the heat seal layer and the heat seal strengths of Mylar® RL32 are intermediate between Mylar® RL31 and Mylar® RL33. Mylar® RL32 and Mylar® RL4 produce similar heat seal strengths to most substrates, but Mylar® RL32 has a greater tendency to produce tearing seals while Mylar® RL4 tends to produce more peelable seals. Like Mylar® RL31, Mylar® RL32 has a lower seal initiation temperature than lidding films with an amorphous polyester heat seal layer (e.g.,Mylar® OL, OL2). This allows good seals to be made at higher line speeds (or using lower sealing temperatures).


Mylar® RL32 can withstand freezing temperatures down to -40℉, and foods can be heated or cooked in contact with this film at temperatures up to 400℉. The oriented polyester base film will begin to distort in the range of 425-450℉.


Special Features
Corona Treatment (Mylar® RL32T): Selected gauges of Mylar® RL32 are available with corona treatment (on the opposite side of film from the heat seal layer) to enhance printing and laminating. This film type is marketed by Mylar® Specialty Films as Mylar® RL32T and is commercially available in nominal 50, 75, 100, and 150 gauges. The film is treated to an initial dyne level of 54. The dyne level of treated lidding films may decline with storage, and in-line corona treatment may be required during subsequent printing or laminating to increase the dyne level to a value adequate to get desired ink or laminate adhesion. Standard put-ups for Mylar® RL32T are the same as shown for Mylar® RL32.

Anti-fog: Mylar® RL32 is not available with anti-fog capability.


Approvals
Food Contact Status - Please contact your Mylar® Specialty Films representative to receive the Regulatory Compliance documents



Disposal
Disposal of Mylar® RL32 does not present special disposal problems. It can be buried as a relatively inert material in a landfill or burned in an incinerator with normal refuse. The incinerator should have sufficient draft to exhaust all combustion products through the stack to avoid exposure to irritating fumes. The disposal method should comply with local, state and federal regulations.


Typical Properties
Available Thickness [Gauge]
50;    100;    150


Property Thickness Value Units Test
BARRIER
Gas Permeability - O2, 24 hr  100  cc/100 in²  ASTM D3985 22℃/50% RH/1 ATM 
Gas Permeability - O2, 24 hr  150  cc/100 in²  ASTM D3985 22℃/50% RH/1 ATM 
Gas Permeability - O2, 24 hr  50  cc/100 in²  ASTM D3985 22℃/50% RH/1 ATM 
WVTR  100  1.3  g/100 in²/day  ASTM F1249 38℃, 90% RH 
WVTR  150  0.9  g/100 in²/day  ASTM F1249 38℃, 90% RH 
WVTR  50  2.8  g/100 in²/day  ASTM F1249 38℃, 90% RH 
 
PHYSICAL
Elongation at Break MD  All  110  ASTM D882A 
Elongation at Break TD  All  80  ASTM D882A 
Modulus  All  550  kpsi  ASTM D822 
Tear (Graves)  100  1.1  lb  ASTM D1004 
Tear (Graves)  150  1.3  lb  ASTM D1004 
Tear (Graves)  50  0.7  lb  ASTM D1004 
Tensile Strength MD (break)  All  25  kpsi  ASTM D882A 
Tensile Strength TD (break)  All  35  kpsi  ASTM D882A 
Unit Weight  100  24.5  lb/ream  ASTM E252 (0.5 m2
Unit Weight  150  35.5  lb/ream  ASTM E252 (0.5 m2
Unit Weight  50  15  lb/ream  ASTM E252 (0.5 m2
Yield (nominal)  100  17,800  in²/lb   
Yield (nominal)  150  12,200  in²/lb   
Yield (nominal)  50  29,500  in²/lb   



Standard Put-ups
Core I.D. (Inches) Roll O.D. (Inches) Thickness (Gauge) Length (Feet)
3 9 1/2 ± 1/4 50 6,600
3 9 1/2 ± 1/4 75 4,900
3 9 1/2 ± 1/4 100 4,200
3 9 1/2 ± 1/4 150 2,900
3 13 ± 1/4 50 13,300
3 13 ± 1/4 75 9,800
3 13 ± 1/4 100 8,500
3 13 ± 1/4 150 5,900
6 11 ± 1/4 50 6,600
6 11 ± 1/4 75 4,900
6 11 ± 1/4 100 4,200
6 11 ± 1/4 150 3,000
6 14 ± 1/4 50 13,000
6 14 ± 1/4 75 9,600
6 14 ± 1/4 100 8,300
6 14 ± 1/4 150 5,800
6 18 ± 1/4 50 23,900
6 18 ± 1/4 75 17,700
6 18 ± 1/4 100 15,200
6 18 ± 1/4 150 10,700



Contact Info
Mylar® Specialty Films U.S. Limited Partnership
3600 Discovery Drive
Chester, VA 23836-6436 USA
Tel: (800) 635-4639
Fax: (804) 530-9867



Disclaimer
Note: These values are typical performance data for Mylar® Specialty Films' polyester film; they are not intended to be used as design data. We believe this information is the best currently available on the subject. It is offered as a possible helpful suggestion in experimentation you may care to undertake along these lines. It is subject to revision as additional knowledge and experience is gained. Mylar® Specialty Films makes no guarantee of results and assumes no obligation or liability whatsoever in connection with this information. This publication is not a license to operate under, or intended to suggest infringement of, any existing patents.

CAUTION: Do not use in medical applications involving permanent implantation in the human body (Mylar® Specialty Films Medical Policy). For other medical applications, see the Medical Caution Statement. Mylar® Specialty Films accepts no liability for use of it's products in medical applications not reviewed and approved by Mylar® Specialty Films or for product misuse. Mylar® Specialty Films supplies products to an agreed specification and does not manufacture products designed specifically for medical end use.

Melinex®, Mylar® and Melinex® STTM are registered trademarks of Mylar® Specialty Films U.S. Limited Partnership.