Mylar® CL is a strong polyester film designed to package foods. Mylar® CL is commercially available in nominal 50 and 100 gauges. The film is typically provided with the sealant side wound toward the core.
|
This film is similar to Mylar® OL2, however, this film will have much stronger seals at temperatures above 180℉ than OL2. This film withstands freezing temperatures down to -40℉.
|
Corona Treatment (Mylar® CLT): Selected gauges of Mylar® CL are available with corona treatment (on the side opposite the heat seal layer) to enhance printing and laminating. This film type is marketed by Mylar® Specialty Films as Mylar® CLT. The film is treated to an initial dyne level of 54. The dyne level of treated lidding films may decline with storage, and in-line corona treatment may be required during subsequent printing or laminating to increase the dyne level to a value adequate to get desired ink or laminate adhesion.
|
This film when laminated to foil makes an excellent inner cap seal for PET containers.
|
Food Contact Status -
Please contact your Mylar® Specialty Films representative to receive the Regulatory Compliance documents.
|
Disposal of Mylar® CL does not present special problems. It can be buried as a relatively inert material in a landfill or burned in an incinerator with normal refuse. The incinerator should have sufficient draft to exhaust all combustion products through the stack to avoid exposure to irritating fumes. The disposal method should comply with local, state and federal regulations.
|
Available Thickness [Gauge] |
50; 100
|
|
|
Property |
Thickness |
Value |
Units |
Test |
BARRIER
|
Gas Permeability - O2, 24 hr |
100 |
5 |
cc/100 in² |
ASTM D3985 22℃/75% RH/1 ATM |
Gas Permeability - O2, 24 hr |
50 |
9 |
cc/100 in² |
ASTM D3985 22℃/75% RH/1 ATM |
WVTR |
100 |
1.3 |
g/100 in2/day |
ASTM F1249 38℃, 90% RH |
WVTR |
50 |
2.8 |
g/100 in2/day |
ASTM F1249 38℃, 90% RH |
|
PHYSICAL
|
Elongation at Break MD |
100 |
140 |
% |
ASTM D882A |
Elongation at Break MD |
50 |
110 |
% |
ASTM D882A |
Elongation at Break TD |
100 |
80 |
% |
ASTM D882A |
Elongation at Break TD |
50 |
80 |
% |
ASTM D882A |
Modulus |
50 - 100 |
550 |
kpsi |
ASTM D822 |
Tear (Graves) |
100 |
1.1 |
lb |
ASTM D1004 |
Tear (Graves) |
50 |
0.7 |
lb |
ASTM D1004 |
Tensile Strength MD (break) |
100 |
27 |
kpsi |
ASTM D882A |
Tensile Strength MD (break) |
50 |
25 |
kpsi |
ASTM D882A |
Tensile Strength TD (break) |
100 |
40 |
kpsi |
ASTM D882A |
Tensile Strength TD (break) |
50 |
35 |
kpsi |
ASTM D882A |
Yield (nominal) |
100 |
20,300 |
in²/lb |
|
Yield (nominal) |
50 |
37,100 |
in²/lb |
|
|
THERMAl
|
Heat Seal Strength |
50 - 100 |
500 |
g/in |
250℉, 0.35 sec, 20 psi |
|
|
Core I.D. (Inches) |
Roll O.D. (Inches) |
Thickness (Gauge) |
Length (Feet) |
3 |
9 1/2 ± 1/4 |
100 |
5,000 |
3 |
13 ± 1/4 |
100 |
10,100 |
6 |
11 ± 1/4 |
100 |
5,000 |
6 |
14 ± 1/4 |
100 |
9,850 |
6 |
18 ± 1/4 |
100 |
18,100 |
3 |
9 ± 1/4 |
50 |
9,300 |
3 |
13 ± 1/4 |
50 |
18,800 |
6 |
11 ± 1/4 |
50 |
9,400 |
6 |
14 ± 1/4 |
50 |
18,400 |
6 |
18 ± 1/4 |
50 |
33,700 |
|
|
Mylar® Specialty Films U.S. Limited Partnership
3600 Discovery Drive
Chester, VA 23836-6436 USA
Tel: (800) 635-4639
Fax: (804) 530-9867
|
Note: These values are typical performance data for Mylar® Specialty Films' polyester film; they are not intended to be used as design data. We believe this information is the best currently available on the subject. It is offered as a possible helpful suggestion in experimentation you may care to undertake along these lines. It is subject to revision as additional knowledge and experience is gained. Mylar® Specialty Films makes no guarantee of results and assumes no obligation or liability whatsoever in connection with this information. This publication is not a license to operate under, or intended to suggest infringement of, any existing patents.
CAUTION: Do not use in medical applications involving permanent implantation in the human body (Mylar® Specialty Films Medical Policy). For other medical applications, see the Medical Caution Statement. Mylar® Specialty Films accepts no liability for use of it's products in medical applications not reviewed and approved by Mylar® Specialty Films or for product misuse. Mylar® Specialty Films supplies products to an agreed specification and does not manufacture products designed specifically for medical end use.
Melinex®, Mylar® and Melinex® STTM are registered trademarks of Mylar® Specialty Films U.S. Limited Partnership.
|
|