MYLAR® CL

Product Description
Mylar® CL is a strong polyester film designed to package foods. Mylar® CL is commercially available in nominal 50 and 100 gauges. The film is typically provided with the sealant side wound toward the core.



General Product Info
This film is similar to Mylar® OL2, however, this film will have much stronger seals at temperatures above 180℉ than OL2. This film withstands freezing temperatures down to -40℉.


Special Features
Corona Treatment (Mylar® CLT): Selected gauges of Mylar® CL are available with corona treatment (on the side opposite the heat seal layer) to enhance printing and laminating. This film type is marketed by Mylar® Specialty Films as Mylar® CLT. The film is treated to an initial dyne level of 54. The dyne level of treated lidding films may decline with storage, and in-line corona treatment may be required during subsequent printing or laminating to increase the dyne level to a value adequate to get desired ink or laminate adhesion.


Typical Applications
This film when laminated to foil makes an excellent inner cap seal for PET containers.


Approvals
Food Contact Status - Please contact your Mylar® Specialty Films representative to receive the Regulatory Compliance documents.



Disposal
Disposal of Mylar® CL does not present special problems. It can be buried as a relatively inert material in a landfill or burned in an incinerator with normal refuse. The incinerator should have sufficient draft to exhaust all combustion products through the stack to avoid exposure to irritating fumes. The disposal method should comply with local, state and federal regulations.


Typical Properties
Available Thickness [Gauge]
50;    100


Property Thickness Value Units Test
BARRIER
Gas Permeability - O2, 24 hr  100  cc/100 in²  ASTM D3985 22℃/75% RH/1 ATM 
Gas Permeability - O2, 24 hr  50  cc/100 in²  ASTM D3985 22℃/75% RH/1 ATM 
WVTR  100  1.3  g/100 in2/day  ASTM F1249 38℃, 90% RH 
WVTR  50  2.8  g/100 in2/day  ASTM F1249 38℃, 90% RH 
 
PHYSICAL
Elongation at Break MD  100  140  ASTM D882A 
Elongation at Break MD  50  110  ASTM D882A 
Elongation at Break TD  100  80  ASTM D882A 
Elongation at Break TD  50  80  ASTM D882A 
Modulus  50 - 100  550  kpsi  ASTM D822 
Tear (Graves)  100  1.1  lb  ASTM D1004 
Tear (Graves)  50  0.7  lb  ASTM D1004 
Tensile Strength MD (break)  100  27  kpsi  ASTM D882A 
Tensile Strength MD (break)  50  25  kpsi  ASTM D882A 
Tensile Strength TD (break)  100  40  kpsi  ASTM D882A 
Tensile Strength TD (break)  50  35  kpsi  ASTM D882A 
Yield (nominal)  100  20,300  in²/lb   
Yield (nominal)  50  37,100  in²/lb   
 
THERMAl
Heat Seal Strength  50 - 100  500  g/in  250℉, 0.35 sec, 20 psi 



Standard Put-ups
Core I.D. (Inches) Roll O.D. (Inches) Thickness (Gauge) Length (Feet)
3 9 1/2 ± 1/4 100 5,000
3 13 ± 1/4 100 10,100
6 11 ± 1/4 100 5,000
6 14 ± 1/4 100 9,850
6 18 ± 1/4 100 18,100
3 9 ± 1/4 50 9,300
3 13 ± 1/4 50 18,800
6 11 ± 1/4 50 9,400
6 14 ± 1/4 50 18,400
6 18 ± 1/4 50 33,700



Contact Info
Mylar® Specialty Films U.S. Limited Partnership
3600 Discovery Drive
Chester, VA 23836-6436 USA
Tel: (800) 635-4639
Fax: (804) 530-9867



Disclaimer
Note: These values are typical performance data for Mylar® Specialty Films' polyester film; they are not intended to be used as design data. We believe this information is the best currently available on the subject. It is offered as a possible helpful suggestion in experimentation you may care to undertake along these lines. It is subject to revision as additional knowledge and experience is gained. Mylar® Specialty Films makes no guarantee of results and assumes no obligation or liability whatsoever in connection with this information. This publication is not a license to operate under, or intended to suggest infringement of, any existing patents.

CAUTION: Do not use in medical applications involving permanent implantation in the human body (Mylar® Specialty Films Medical Policy). For other medical applications, see the Medical Caution Statement. Mylar® Specialty Films accepts no liability for use of it's products in medical applications not reviewed and approved by Mylar® Specialty Films or for product misuse. Mylar® Specialty Films supplies products to an agreed specification and does not manufacture products designed specifically for medical end use.

Melinex®, Mylar® and Melinex® STTM are registered trademarks of Mylar® Specialty Films U.S. Limited Partnership.