Welcome, Guest Current Language:   US
  Home | Welcome Page | Film Type Selector | Market Locator | Product Locator
 

Show Printable Version  
 
MYLAR® LBT

Product Description
Mylar® LBT is an uncoated, transparent polyeser film that has been corona treated on one side to provide superior wetting and adhesion of inks, primers and adhesives. Mylar® LBT is commercially available in nominal 48, 75 and 92 gauges. Other gauges may be available upon request. The standard wind-up presents the corona-treated side facing the roll core.

General Product Info
In addition to the enhanced wettability offered to inks, primers, adhesives and coatings, Mylar® LBT offers all of the properties attributed to Mylar® LB, including high levels of strength, temperature resistance and flavor and odor barriers. Its sparkling clarity and insensitivity to humidity make Mylar® LBT a preferred print carrier.

Typical Applications
Mylar® LBT typically is used as the reverse printed outer ply of a lamination with inner plies providing additional oxygen barrier if needed, as well as heat sealability. The availability of the two-side corona-treated Mylar® LBT2 permits use where the ply will be buried inside a lamination with bonding to both surfaces or where the exposed outer surface will subsequently receive surface printing, code dating or some for of package lot identification.

Approvals
Food Contact Status - Please contact your Mylar® Specialty Films representative to receive the Regulatory Compliance documents
UL Recognition - Product has been registered with Underwriters Laboratories.


Disposal
Dispose of in compliance with federal, state and local regulations. Preferred options for disposal are (1) recycling, (2) incineration with energy recovery and (3) landfill. The high fuel value of this product makes option No. 2 very desirable for material that cannot be recycled.

Typical Properties
Available Thickness [Gauge]
48;    75;    92


Property Thickness Value Units Test
BARRIER
Gas Permeability - O2, 24 hr  48  cc/100 in²  ASTM D3985 22℃/75% RH/1 ATM 
Gas Permeability - O2, 24 hr  75  cc/100 in²  ASTM D3985 22℃/75% RH/1 ATM 
Gas Permeability - O2, 24 hr  92  cc/100 in²  ASTM D3985 22℃/75% RH/1 ATM 
WVTR  48  2.8  g/100 in²/day  ASTM F1249 38℃, 90% RH 
WVTR  75  1.9  g/100 in²/day  ASTM F1249 38℃, 90% RH 
WVTR  92  1.3  g/100 in²/day  ASTM F1249 38℃, 90% RH 
 
OPTICAL
Clarity  48  76  ASTM D1746 
Clarity  75  73  ASTM D1746 
Clarity  92  70  ASTM D1746 
Gloss 20 Degrees  48  200    ASTM D2457 
Gloss 20 Degrees  75  180    ASTM D2457 
Gloss 20 Degrees  92  150    ASTM D2457 
Haze  48  4.0  ASTM D1003 
Haze  75  5.5  ASTM D1003 
Haze  92  6.0  ASTM D1003 
 
PHYSICAL
Elongation at Break MD  48  110  ASTM D882A 
Elongation at Break MD  75  130  ASTM D882A 
Elongation at Break MD  92  140  ASTM D882A 
Elongation at Break TD  48  80  ASTM D882A 
Elongation at Break TD  75  100  ASTM D882A 
Elongation at Break TD  92  80  ASTM D882A 
Modulus  48 - 92  550  kpsi  ASTM D822 
Tear (Graves)  48  0.7  lb  ASTM D1004 
Tear (Graves)  75  0.9  lb  ASTM D1004 
Tear (Graves)  92  1.1  lb  ASTM D1004 
Tensile Strength MD (break)  48  27  kpsi  ASTM D882A 
Tensile Strength MD (break)  75  29  kpsi  ASTM D882A 
Tensile Strength MD (break)  92  27  kpsi  ASTM D882A 
Tensile Strength TD (break)  48  34  kpsi  ASTM D882A 
Tensile Strength TD (break)  75  35  kpsi  ASTM D882A 
Tensile Strength TD (break)  92  40  kpsi  ASTM D882A 
Unit Weight  48  10.4  in²/lb  ASTM E252 (0.5 m2
Unit Weight  75  16.2  in²/lb  ASTM E252 (0.5 m2
Unit Weight  92  19.7  in²/lb  ASTM E252 (0.5 m2
Yield (nominal)  48  41,700  in²/lb   
Yield (nominal)  75  26,700  in²/lb   
Yield (nominal)  92  22,000  in²/lb   
 
THERMAL
Shrinkage MD (150℃)  48  2.2  Unrestrained @ 150℃/30 min 
Shrinkage MD (150℃)  75  2.2  Unrestrained @ 150℃/30 min 
Shrinkage MD (150℃)  92  1.6  Unrestrained @ 150℃/30 min 
Shrinkage TD (150℃)  48  1.3  Unrestrained @ 150℃/30 min 
Shrinkage TD (150℃)  75  1.1  Unrestrained @ 150℃/30 min 
Shrinkage TD (150℃)  92  1.6  Unrestrained @ 150℃/30 min 


Standard Put-ups
Core I.D. (Inches) Roll O.D. (Inches) Thickness (Gauge) Length (Feet)
3 9 1/2 ± 1/4 48 10,600
3 9 1/2 ± 1/4 75 6,800
3 9 1/2 ± 1/4 92 5,600
3 13 ± 1/4 48 21,300
3 13 ± 1/4 75 13,600
3 13 ± 1/4 92 11,200
3 18 ± 1/4 48 42,400
3 18 ± 1/4 75 27,200
3 18 ± 1/4 92 22,300
6 11 ± 1/4 48 10,600
6 11 ± 1/4 75 6,800
6 11 ± 1/4 92 5,600
6 14 ± 1/4 48 20,800
6 14 ± 1/4 75 13,400
6 14 ± 1/4 92 11,000
6 18 ± 1/4 48 38,300
6 18 ± 1/4 75 24,500
6 18 ± 1/4 92 20,200
6 22 1/2 ± 1/4 48 63,100
6 22 1/2 ± 1/4 75 40,400
6 22 1/2 ± 1/4 92 33,200
6 24 ± 1/4 48 72,600
6 24 ± 1/4 75 46,500
6 24 ± 1/4 92 38,200


Contact Info
Mylar® Specialty Films U.S. Limited Partnership
3600 Discovery Drive
Chester, VA 23836-6436 USA
Tel: (800) 635-4639
Fax: (804) 530-9867


Disclaimer
Note: These values are typical performance data for Mylar® Specialty Films' polyester film; they are not intended to be used as design data. We believe this information is the best currently available on the subject. It is offered as a possible helpful suggestion in experimentation you may care to undertake along these lines. It is subject to revision as additional knowledge and experience is gained. Mylar® Specialty Films makes no guarantee of results and assumes no obligation or liability whatsoever in connection with this information. This publication is not a license to operate under, or intended to suggest infringement of, any existing patents.

CAUTION: Do not use in medical applications involving permanent implantation in the human body (Mylar® Specialty Films Medical Policy). For other medical applications, see the Medical Caution Statement. Mylar® Specialty Films accepts no liability for use of it's products in medical applications not reviewed and approved by Mylar® Specialty Films or for product misuse. Mylar® Specialty Films supplies products to an agreed specification and does not manufacture products designed specifically for medical end use.

Melinex®, Mylar® and Melinex® STTM are registered trademarks of Mylar® Specialty Films U.S. Limited Partnership.
 
  Show Printable Version
 
  Copyright © 2024 Mylar® Specialty Films. All rights reserved. | Privacy
  Developed and Powered by Client Centered Technologies, Inc.