Welcome, Guest Current Language:   US
  Home | Welcome Page | Film Type Selector | Market Locator | Product Locator
 

Show Printable Version  
 
MYLAR® EL

Product Description
Mylar® EL films, typically 48 through 500 gauge are strong, tough, general -purpose films for electrical/electronic uses. Heavier gauges of Mylar® EL films are similar to Mylar® MO films. Available in grades from transparent to hazy, Mylar® EL films offer chemical inertness, good dielectrics, high temperature durability, and good handling characteristics.

General Product Info
The superior electrical, mechanical, thermal, and chemical inertness characteristics of Mylar® type EL films make them ideally suited for electrical and electronic applications.

Typical Applications
The outstanding strength, flexibility, and electrical properties of Mylar® type EL films make them well suited for many electrical and electronics applications. The good handling and winding characteristics make them especially suitable for coating, die cutting, embossing, and laminating operations.

Approvals
UL Recognition - Product has been registered with Underwriters Laboratories.


Typical Properties
Available Thickness [Gauge]
48;    75;    92;    142;    200;    300;    400;    500


Property Thickness Value Units Test
ELECTRICAL
Breakdown Voltage  48  2.8  kV  ASTM D149 1/4" electrode 500 V/sec 25°C in air 
Breakdown Voltage  75  3.5  kV  ASTM D149 1/4" electrode 500 V/sec 25°C in air 
Breakdown Voltage  92  4.0  kV  ASTM D149 1/4" electrode 500 V/sec 25°C in air 
Breakdown Voltage  142  5.5  kV  ASTM D149 1/4" electrode 500 V/sec 25°C in air 
Breakdown Voltage  200  7.7  kV  ASTM D149 1/4" electrode 500 V/sec 25°C in air 
Breakdown Voltage  300  10.0  kV  ASTM D149 1/4" electrode 500 V/sec 25°C in air 
Breakdown Voltage  400  11.7  kV  ASTM D149 1/4" electrode 500 V/sec 25°C in air 
Breakdown Voltage  500  13.5  kV  ASTM D149 1/4" electrode 500 V/sec 25°C in air 
 
OPTICAL
Haze  48  ASTM D1003 
Haze  75  ASTM D1003 
Haze  92  16  ASTM D1003 
Haze  142  18  ASTM D1003 
Haze  200  24  ASTM D1003 
Haze  300  29  ASTM D1003 
Haze  400  37  ASTM D1003 
Haze  500  43  ASTM D1003 
 
PHYSICAL
Elongation at Break MD  48  124  ASTM D882A 
Elongation at Break MD  75  134  ASTM D882A 
Elongation at Break MD  92  110  ASTM D882A 
Elongation at Break MD  142  125  ASTM D882A 
Elongation at Break MD  200  135  ASTM D882A 
Elongation at Break MD  300  135  ASTM D882A 
Elongation at Break MD  400  140  ASTM D882A 
Elongation at Break MD  500  140  ASTM D882A 
Elongation at Break TD  48  88  ASTM D882A 
Elongation at Break TD  75  103  ASTM D882A 
Elongation at Break TD  92  90  ASTM D882A 
Elongation at Break TD  142  100  ASTM D882A 
Elongation at Break TD  200  110  ASTM D882A 
Elongation at Break TD  300  110  ASTM D882A 
Elongation at Break TD  400  115  ASTM D882A 
Elongation at Break TD  500  115  ASTM D882A 
Tensile Strength MD  48  29  kpsi  ASTM D882A 
Tensile Strength MD  75  31  kpsi  ASTM D882A 
Tensile Strength MD  92  28  kpsi  ASTM D882A 
Tensile Strength MD  142  28  kpsi  ASTM D882A 
Tensile Strength MD  200  28  kpsi  ASTM D882A 
Tensile Strength MD  300  27  kpsi  ASTM D882A 
Tensile Strength MD  400  26  kpsi  ASTM D882A 
Tensile Strength MD  500  27  kpsi  ASTM D882A 
Tensile Strength TD  48  34  kpsi  ASTM D882A 
Tensile Strength TD  75  36  kpsi  ASTM D882A 
Tensile Strength TD  92  34  kpsi  ASTM D882A 
Tensile Strength TD  142  34  kpsi  ASTM D882A 
Tensile Strength TD  200  33  kpsi  ASTM D882A 
Tensile Strength TD  300  31  kpsi  ASTM D882A 
Tensile Strength TD  400  30  kpsi  ASTM D882A 
Tensile Strength TD  500  30  kpsi  ASTM D882A 
Yield (nominal)  48  41,300  in²/lb   
Yield (nominal)  75  26,500  in²/lb   
Yield (nominal)  92  21,800  in²/lb   
Yield (nominal)  142  14,000  in²/lb   
Yield (nominal)  200  9,900  in²/lb   
Yield (nominal)  300  6,600  in²/lb   
Yield (nominal)  400  5,000  in²/lb   
Yield (nominal)  500  4,000  in²/lb   
 
THERMAL
Shrinkage MD (150°C)  48  2.0  Unrestrained @ 150°C/30 min 
Shrinkage MD (150°C)  75  2.0  Unrestrained @ 150°C/30 min 
Shrinkage MD (150°C)  92  1.9  Unrestrained @ 150°C/30 min 
Shrinkage MD (150°C)  142  1.5  Unrestrained @ 150°C/30 min 
Shrinkage MD (150°C)  200  1.3  Unrestrained @ 150°C/30 min 
Shrinkage MD (150°C)  300  1.2  Unrestrained @ 150°C/30 min 
Shrinkage MD (150°C)  400  1.1  Unrestrained @ 150°C/30 min 
Shrinkage MD (150°C)  500  1.1  Unrestrained @ 150°C/30 min 
Shrinkage TD (150°C)  48  1.5  Unrestrained @ 150°C/30 min 
Shrinkage TD (150°C)  75  1.4  Unrestrained @ 150°C/30 min 
Shrinkage TD (150°C)  92  1.1  Unrestrained @ 150°C/30 min 
Shrinkage TD (150°C)  142  1.0  Unrestrained @ 130°C/30 min 
Shrinkage TD (150°C)  200  0.8  Unrestrained @ 150°C/30 min 
Shrinkage TD (150°C)  300  0.8  Unrestrained @ 150°C/30 min 
Shrinkage TD (150°C)  400  0.7  Unrestrained @ 150°C/30 min 
Shrinkage TD (150°C)  500  0.7  Unrestrained @ 150°C/30 min 


Standard Put-ups
Core I.D. (Inches) Roll O.D. (Inches) Thickness (Gauge) Length (Feet)
3 9 1/2 48 10,500
3 9 1/2 75 6,700
3 9 1/2 92 5,400
3 9 1/2 142 3,500
3 9 1/2 200 2,500
3 9 1/2 300 1,650
3 9 1/2 400 1,250
3 9 1/2 500 1,000
10 (Master roll) 48 63,000
10 (Master roll) 75 59,000
10 (Master roll) 92 47,700
10 (Master roll) 142 30,600
10 (Master roll) 200 21,950
10 (Master roll) 300 14,650
10 (Master roll) 400 10,980
10 (Master roll) 500 8,850


Contact Info
DuPont Teijin Films U.S. Limited Partnership
3600 Discovery Drive
Chester, VA 23836 USA
Tel: (800) 635-4639
Fax: (804) 530-9867


Disclaimer
Note: These values are typical performance data for DuPont Teijin Films' polyester film; they are not intended to be used as design data. We believe this information is the best currently available on the subject. It is offered as a possible helpful suggestion in experimentation you may care to undertake along these lines. It is subject to revision as additional knowledge and experience is gained. DuPont Teijin Films makes no guarantee of results and assumes no obligation or liability whatsoever in connection with this information. This publication is not a license to operate under, or intended to suggest infringement of, any existing patents.

CAUTION: Do not use in medical applications involving permanent implantation in the human body (DuPont Teijin Films Medical Policy). For other medical applications, see the Medical Caution Statement. DuPont Teijin Films accepts no liability for use of it's products in medical applications not reviewed and approved by DuPont Teijin Films or for product misuse. DuPont Teijin Films supplies products to an agreed specification and does not manufacture products designed specifically for medical end use.

Melinex®, Mylar® and Melinex® STTM are registered trademarks of DuPont Teijin Films U.S. Limited Partnership.
 
  Show Printable Version
 
  Copyright © 2006 DuPont Teijin Films. All rights reserved. | Privacy
  Developed and Powered by Client Centered Technologies, Inc.