Welcome, Guest Current Language:   US
  Home | Welcome Page | Film Type Selector | Market Locator | Product Locator
 

Show Printable Version  
 
MYLAR® EB11

Product Description
MYLAR® EB11 is a low gloss polyester film with a matte surface. It is typically used as a carrier film. It is commercially available in nominal 48 - 300 gauge.

General Product Info
MYLAR® EB11 is a low gloss, hazy product. Reverse side printing is superb, and metallized EB11 offers muted matte appearance. EB11 provides an excellent, low gloss surface texture transfer when used as a carrier film.

Approvals
Food Contact Status - Please contact your DuPont Teijin Films representative to receive the Regulatory Compliance documents


Typical Properties
Available Thickness [Gauge]
48;    92;    142;    200;    300


Property Thickness Value Units Test
OPTICAL
Gloss 60 Degrees  48  34  ASTM D2457 - 90 
Gloss 60 Degrees  92  52  ASTM D2457 - 90 
Gloss 60 Degrees  142  53  ASTM D2457 - 90 
Gloss 60 Degrees  200  60  ASTM D2457 - 90 
Gloss 60 Degrees  300  63  ASTM D2457 - 90 
Haze  48  55  ASTM D1003 
Haze  92  65  ASTM D1003 
Haze  142  70  ASTM D1003 
Haze  200  77  ASTM D1003 
Haze  300  85  ASTM D1003 
Total Light Transmission (TLT)  48  80  ASTM D1003 
Total Light Transmission (TLT)  92  84  ASTM D1003 
Total Light Transmission (TLT)  142  83  ASTM D1003 
Total Light Transmission (TLT)  200  82  ASTM D1003 
Total Light Transmission (TLT)  300  81  ASTM D1003 
 
PHYSICAL
Elongation at Break MD  48  100  ASTM D882A 
Elongation at Break MD  92  130  ASTM D882A 
Elongation at Break MD  142  150  ASTM D882A 
Elongation at Break MD  200  155  ASTM D882A 
Elongation at Break MD  300  170  ASTM D882A 
Elongation at Break TD  48  75  ASTM D882A 
Elongation at Break TD  92  75  ASTM D882A 
Elongation at Break TD  142  80  ASTM D882A 
Elongation at Break TD  200  85  ASTM D882A 
Elongation at Break TD  300  100  ASTM D882A 
Tensile Strength MD (break)  48 - 300  19,000  psi  ASTM D882A 
Tensile Strength TD (break)  48 - 300  29,000  psi  ASTM D882A 
 
THERMAL
Shrinkage MD (190°C)  48 - 300  3.2  Unrestrained @ 190°C/5 min 
Shrinkage TD (190°C)  48 - 300  2.4  Unrestrained @ 190°C/5 min 


Contact Info
DuPont Teijin Films U.S. Limited Partnership
3600 Discovery Drive
Chester, VA 23836 USA
Tel: (800) 635-4639
Fax: (804) 530-9867


Disclaimer
Note: These values are typical performance data for DuPont Teijin Films' polyester film; they are not intended to be used as design data. We believe this information is the best currently available on the subject. It is offered as a possible helpful suggestion in experimentation you may care to undertake along these lines. It is subject to revision as additional knowledge and experience is gained. DuPont Teijin Films makes no guarantee of results and assumes no obligation or liability whatsoever in connection with this information. This publication is not a license to operate under, or intended to suggest infringement of, any existing patents.

CAUTION: Do not use in medical applications involving permanent implantation in the human body (DuPont Teijin Films Medical Policy). For other medical applications, see the Medical Caution Statement. DuPont Teijin Films accepts no liability for use of it's products in medical applications not reviewed and approved by DuPont Teijin Films or for product misuse. DuPont Teijin Films supplies products to an agreed specification and does not manufacture products designed specifically for medical end use.

Melinex®, Mylar® and Melinex® STTM are registered trademarks of DuPont Teijin Films U.S. Limited Partnership.
 
  Show Printable Version
 
  Copyright © 2006 DuPont Teijin Films. All rights reserved. | Privacy
  Developed and Powered by Client Centered Technologies, Inc.