Available Thickness [Gauge]
48;    92;    142;    200;    300


Property Thickness Value Units Test
OPTICAL
Gloss 60 Degrees  48  34  ASTM D2457 - 90 
Gloss 60 Degrees  92  52  ASTM D2457 - 90 
Gloss 60 Degrees  142  53  ASTM D2457 - 90 
Gloss 60 Degrees  200  60  ASTM D2457 - 90 
Gloss 60 Degrees  300  63  ASTM D2457 - 90 
Haze  48  55  ASTM D1003 
Haze  92  65  ASTM D1003 
Haze  142  70  ASTM D1003 
Haze  200  77  ASTM D1003 
Haze  300  85  ASTM D1003 
Total Light Transmission (TLT)  48  80  ASTM D1003 
Total Light Transmission (TLT)  92  84  ASTM D1003 
Total Light Transmission (TLT)  142  83  ASTM D1003 
Total Light Transmission (TLT)  200  82  ASTM D1003 
Total Light Transmission (TLT)  300  81  ASTM D1003 
 
PHYSICAL
Elongation at Break MD  48  100  ASTM D882A 
Elongation at Break MD  92  130  ASTM D882A 
Elongation at Break MD  142  150  ASTM D882A 
Elongation at Break MD  200  155  ASTM D882A 
Elongation at Break MD  300  170  ASTM D882A 
Elongation at Break TD  48  75  ASTM D882A 
Elongation at Break TD  92  75  ASTM D882A 
Elongation at Break TD  142  80  ASTM D882A 
Elongation at Break TD  200  85  ASTM D882A 
Elongation at Break TD  300  100  ASTM D882A 
Tensile Strength MD (break)  48 - 300  19,000  psi  ASTM D882A 
Tensile Strength TD (break)  48 - 300  29,000  psi  ASTM D882A 
 
THERMAL
Shrinkage MD (190℃)  48 - 300  3.2  Unrestrained @ 190℃/5 min 
Shrinkage TD (190℃)  48 - 300  2.4  Unrestrained @ 190℃/5 min 



Contact Info
Mylar® Specialty Films U.S. Limited Partnership
3600 Discovery Drive
Chester, VA 23836-6436 USA
Tel: (800) 635-4639
Fax: (804) 530-9867



Disclaimer
Note: These values are typical performance data for Mylar® Specialty Films' polyester film; they are not intended to be used as design data. We believe this information is the best currently available on the subject. It is offered as a possible helpful suggestion in experimentation you may care to undertake along these lines. It is subject to revision as additional knowledge and experience is gained. Mylar® Specialty Films makes no guarantee of results and assumes no obligation or liability whatsoever in connection with this information. This publication is not a license to operate under, or intended to suggest infringement of, any existing patents.

CAUTION: Do not use in medical applications involving permanent implantation in the human body (Mylar® Specialty Films Medical Policy). For other medical applications, see the Medical Caution Statement. Mylar® Specialty Films accepts no liability for use of it's products in medical applications not reviewed and approved by Mylar® Specialty Films or for product misuse. Mylar® Specialty Films supplies products to an agreed specification and does not manufacture products designed specifically for medical end use.

Melinex®, Mylar® and Melinex® STTM are registered trademarks of Mylar® Specialty Films U.S. Limited Partnership.