Mylar® 814 is a one-side pretreated polyester film which was designed for UV cure inks and also works well for EB cure overlaquers..
|
Mylar® 814 is designed to provide excellent adhesion with print systems using UV cure. It can also be used with solvent or aqueous based print systems and EB cure overlaquers.
|
Food Contact Status -
Please contact your Mylar® Specialty Films representative to receive the Regulatory Compliance documents
|
Available Thickness [Gauge] |
48
|
|
|
Property |
Thickness |
Value |
Units |
Test |
BARRIER
|
Gas Permeability (Base film) |
48 |
6.0 |
cc/100 in² |
ASTM D1434 (24 hrs @ 77℉ and 75% RH @ 1 ATM) |
|
OPTICAL
|
Total Light Transmission (TLT) |
48 |
90 |
% |
ASTM D1003 |
|
PHYSICAL
|
C.O.F. (dynamic) A-B |
48 |
0.4 |
in²/lb |
ASTM D1894 |
C.O.F. (static) |
48 |
0.5 |
|
ASTM D1894 |
Density |
48 |
1.40 |
g/cc |
|
Elongation at Break MD |
48 |
110 |
% |
ASTM D882A |
Elongation at Break TD |
48 |
70 |
% |
ASTM D882A |
Tensile Strength MD |
48 |
31,000 |
psi |
ASTM D882A |
Tensile Strength TD |
48 |
42,000 |
psi |
ASTM D882A |
Yield (nominal) |
48 |
42,200 |
psi |
|
|
THERMAL
|
Shrinkage MD (150℃) |
48 |
1.25 |
% |
150℃ (302℉), 30 min |
|
|
Mylar® Specialty Films U.S. Limited Partnership
3600 Discovery Drive
Chester, VA 23836-6436 USA
Tel: (800) 635-4639
Fax: (804) 530-9867
|
Note: These values are typical performance data for Mylar® Specialty Films' polyester film; they are not intended to be used as design data. We believe this information is the best currently available on the subject. It is offered as a possible helpful suggestion in experimentation you may care to undertake along these lines. It is subject to revision as additional knowledge and experience is gained. Mylar® Specialty Films makes no guarantee of results and assumes no obligation or liability whatsoever in connection with this information. This publication is not a license to operate under, or intended to suggest infringement of, any existing patents.
CAUTION: Do not use in medical applications involving permanent implantation in the human body (Mylar® Specialty Films Medical Policy). For other medical applications, see the Medical Caution Statement. Mylar® Specialty Films accepts no liability for use of it's products in medical applications not reviewed and approved by Mylar® Specialty Films or for product misuse. Mylar® Specialty Films supplies products to an agreed specification and does not manufacture products designed specifically for medical end use.
Melinex®, Mylar® and Melinex® STTM are registered trademarks of Mylar® Specialty Films U.S. Limited Partnership.
|
|