Mylar® 851H (also called Mylar® 851) is a co-extruded, one side amorphous, heat sealable polyester film designed to be used in metallization, print, and lamination applications. This film is suitable for use in contact with food. Mylar® 851H has a thicker heat sealable layer than Mylar® 850H.
|
This product is similar to Mylar® 850H, however, the amorphous heat seal layer is thicker.
|
Food Contact Status -
Please contact your Mylar® Specialty Films representative to receive the Regulatory Compliance documents
|
Available Thickness [Gauge] |
60
|
|
|
Property |
Thickness |
Value |
Units |
Test |
BARRIER
|
Gas Permeability - O2, 24 hr |
60 |
5.0 |
cc/100 in² |
ASTM D1434 77℉/75% RH/1 ATM |
|
OPTICAL
|
Haze |
60 |
3.5 |
% |
ASTM D1003 |
Total Light Transmission (TLT) |
60 |
88.6 |
% |
ASTM D1003 |
|
PHYSICAL
|
C.O.F. (dynamic) A-B |
60 |
0.5 |
|
ASTM D1894 |
C.O.F. (static) |
60 |
0.6 |
|
ASTM D1894 |
Density |
|
1.40 |
g/cc |
|
Elongation at Break MD |
|
100 |
% |
ASTM D882A |
Elongation at Break TD |
|
90 |
% |
ASTM D882A |
Tensile Strength MD |
60 |
25 |
kpsi |
ASTM D882A |
Tensile Strength TD |
60 |
27 |
kpsi |
ASTM D882A |
Yield (nominal) |
60 |
33,000 |
in²/lb |
|
|
THERMAL
|
Heat Seal Strength (HS/HS) |
60 |
1000 |
gm/25mm |
285℉, 1 sec, 40 psi |
Heat Seal Temp. Range |
60 |
220-400 |
°F |
|
Shrinkage MD (150℃) |
60 |
1.25 |
% |
Unrestrained @ 150℃/30 min |
Shrinkage TD (150℃) |
60 |
0.3 |
% |
Unrestrained @ 150℃/30 min |
|
|
Mylar® Specialty Films U.S. Limited Partnership
3600 Discovery Drive
Chester, VA 23836-6436 USA
Tel: (800) 635-4639
Fax: (804) 530-9867
|
Note: These values are typical performance data for Mylar® Specialty Films' polyester film; they are not intended to be used as design data. We believe this information is the best currently available on the subject. It is offered as a possible helpful suggestion in experimentation you may care to undertake along these lines. It is subject to revision as additional knowledge and experience is gained. Mylar® Specialty Films makes no guarantee of results and assumes no obligation or liability whatsoever in connection with this information. This publication is not a license to operate under, or intended to suggest infringement of, any existing patents.
CAUTION: Do not use in medical applications involving permanent implantation in the human body (Mylar® Specialty Films Medical Policy). For other medical applications, see the Medical Caution Statement. Mylar® Specialty Films accepts no liability for use of it's products in medical applications not reviewed and approved by Mylar® Specialty Films or for product misuse. Mylar® Specialty Films supplies products to an agreed specification and does not manufacture products designed specifically for medical end use.
Melinex®, Mylar® and Melinex® STTM are registered trademarks of Mylar® Specialty Films U.S. Limited Partnership.
|
|