Product Description
Mylar® 840 is a one-side pretreated polyester film for improved metal or cold seal adhesion. The packaging industry is constantly setting higher standards for product protection using flexible packaging films. Improved barriers as well as package strength and stiffness are key characteristics of Mylar® 840 polyester which has made it a premier packaging film.


Approvals
Food Contact Status - Please contact your Mylar® Specialty Films representative to receive the Regulatory Compliance documents



Typical Properties
Available Thickness [Gauge]
48


Property Thickness Value Units Test
BARRIER
Gas Permeability - Carbon Dioxide  48  31.0  cc/100 in²  ASTM D1434 (24 hrs @ 77℉ and 75% RH @ 1 ATM) 
Gas Permeability - Nitrogen  48  1.6  cc/100 in²  ASTM D1434 (24 hrs @ 77℉ and 75% RH @ 1 ATM) 
 
OPTICAL
Total Light Transmission (TLT)  48  88.5  ASTM D1003 
 
PHYSICAL
Bond Strength @ Ambient Conditions (metallized)  48  750  77℉ and 50% RH 
C.O.F. (dynamic) A-B  48  0.4    ASTM D1894 
C.O.F. (static)  48  0.5    ASTM D1894 
Density  48  1.40  g/cc   
Elongation at Break MD  48  110  ASTM D882A 
Elongation at Break TD  48  80  ASTM D882A 
Tensile Strength MD  48  32,000  psi  ASTM D882A 
Tensile Strength TD  48  38,000  psi  ASTM D882A 
Yield (nominal)  48  42,200  in²/lb   
 
THERMAL
Shrinkage MD (150℃)  48  1.26  Unrestrained @ 150℃/30 min 
Shrinkage TD (150℃)  48  1.28  Unrestrained @ 150℃/30 min 



Contact Info
Mylar® Specialty Films U.S. Limited Partnership
3600 Discovery Drive
Chester, VA 23836-6436 USA
Tel: (800) 635-4639
Fax: (804) 530-9867



Disclaimer
Note: These values are typical performance data for Mylar® Specialty Films' polyester film; they are not intended to be used as design data. We believe this information is the best currently available on the subject. It is offered as a possible helpful suggestion in experimentation you may care to undertake along these lines. It is subject to revision as additional knowledge and experience is gained. Mylar® Specialty Films makes no guarantee of results and assumes no obligation or liability whatsoever in connection with this information. This publication is not a license to operate under, or intended to suggest infringement of, any existing patents.

CAUTION: Do not use in medical applications involving permanent implantation in the human body (Mylar® Specialty Films Medical Policy). For other medical applications, see the Medical Caution Statement. Mylar® Specialty Films accepts no liability for use of it's products in medical applications not reviewed and approved by Mylar® Specialty Films or for product misuse. Mylar® Specialty Films supplies products to an agreed specification and does not manufacture products designed specifically for medical end use.

Melinex®, Mylar® and Melinex® STTM are registered trademarks of Mylar® Specialty Films U.S. Limited Partnership.