Mylar® 822 is a polyester film that has been chemically pretreated on one side. It is designed for printing and extruded polyethylene adhesion.
|
The following diagrams are examples of how Mylar® 822 can be used.
|
Food Contact Status -
Please contact your Mylar® Specialty Films representative to receive the Regulatory Compliance documents
|
Available Thickness [Gauge] |
48; 92; 200
|
|
|
Property |
Thickness |
Value |
Units |
Test |
BARRIER
|
Gas Permeability - O2, 24 hr |
48 |
6 |
cc/100 in² |
ASTM D1434 77℉/75% RH/1 ATM |
WVTR |
48 |
2.8 |
g/100 in²/day |
ASTM F1249 38℃, 90% RH |
|
OPTICAL
|
Haze |
200 |
8.8 |
% |
ASTM D1003 |
Haze |
48 |
3.8 |
% |
ASTM D1003 |
Haze |
92 |
5.7 |
% |
ASTM D1003 |
|
PHYSICAL
|
C.O.F. (dynamic) |
48-200 |
0.4 |
|
ASTM D1894 |
C.O.F. (static) |
48 |
0.5 |
|
ASTM D1894 |
Density |
48-200 |
1.40 |
g/cc |
|
Elongation at Break MD |
200 |
150 |
% |
ASTM D882A |
Elongation at Break MD |
48 |
110 |
% |
ASTM D882A |
Elongation at Break MD |
92 |
130 |
% |
ASTM D882A |
Elongation at Break TD |
200 |
110 |
% |
ASTM D882A |
Elongation at Break TD |
48 |
70 |
% |
ASTM D882A |
Elongation at Break TD |
92 |
90 |
% |
ASTM D882A |
Tensile Strength MD (break) |
48-200 |
28,500 |
psi |
ASTM D882A |
Tensile Strength TD (break) |
200 |
33,000 |
psi |
ASTM D882A |
Tensile Strength TD (break) |
48 & 92 |
36,000 |
psi |
ASTM D882A |
|
THERMAL
|
Shrinkage MD (190℃) |
48-200 |
3 |
% |
Unrestrained @ 190℃/5 min |
Shrinkage TD (190℃) |
200 |
0.6 |
% |
Unrestrained @ 190℃/5 min |
Shrinkage TD (190℃) |
48 & 92 |
1.3 |
% |
Unrestrained @ 190℃/5 min |
|
|
Mylar® Specialty Films U.S. Limited Partnership
3600 Discovery Drive
Chester, VA 23836-6436 USA
Tel: (800) 635-4639
Fax: (804) 530-9867
|
Note: These values are typical performance data for Mylar® Specialty Films' polyester film; they are not intended to be used as design data. We believe this information is the best currently available on the subject. It is offered as a possible helpful suggestion in experimentation you may care to undertake along these lines. It is subject to revision as additional knowledge and experience is gained. Mylar® Specialty Films makes no guarantee of results and assumes no obligation or liability whatsoever in connection with this information. This publication is not a license to operate under, or intended to suggest infringement of, any existing patents.
CAUTION: Do not use in medical applications involving permanent implantation in the human body (Mylar® Specialty Films Medical Policy). For other medical applications, see the Medical Caution Statement. Mylar® Specialty Films accepts no liability for use of it's products in medical applications not reviewed and approved by Mylar® Specialty Films or for product misuse. Mylar® Specialty Films supplies products to an agreed specification and does not manufacture products designed specifically for medical end use.
Melinex®, Mylar® and Melinex® STTM are registered trademarks of Mylar® Specialty Films U.S. Limited Partnership.
|
|