MYLAR® 813

Product Description
Mylar® 813 is a clear, pretreated base film with high gloss, low haze, and excellent processability. It is a one side pre-treated polyester designed for improved ink adhesion.


General Product Info
Mylar® 813 film provides good clarity for reverse printing and allows inks to shine through with high quality. The film's pretreated surface also provides improved adhesion for various coatings and adhesives, often eliminating the need for any type of priming operation. The chemical pretreatment on Mylar® 813 film does not result in a performance or shelf life decline over time, and generally is superior to corona treated film.


Mylar® 813 film features good clarity and handling characteristics in metallizing operations. When aluminum metallized, the film exhibits excellent aesthetic quality as well as the best barrier to oxygen and moisture in a flexible packaging film.


Polyester is more thermally stable at higher temperatures and has higher tensile strength than materials such as polypropylene or polyethylene. Mylar® polyester film also maintains an excellent film thickness profile and roll formation to ensure consistent processability in your operations. These characteristics are particularly important in complex, multi-stage printing operations where holding print register is critical to print quality. As print complexity, quality and speeds increase, Mylar® film provides a cost-effective solution for the packaging industry.


Approvals
Food Contact Status - Please contact your Mylar® Specialty Films representative to receive the Regulatory Compliance documents



Typical Properties
Available Thickness [Gauge]
48;    92


Property Thickness Value Units Test
BARRIER
Gas Permeability - Carbon Dioxide  48  31.0  cc/100 in²  ASTM D1434 (24 hrs @ 77℉ and 75% RH @ 1 ATM) 
Gas Permeability - Nitrogen  48  1.6  cc/100 in²  ASTM D1434 (24 hrs @ 77℉ and 75% RH @ 1 ATM) 
Gas Permeability - O2, 24 hr  48  6.0  cc/100 sq in  ASTM D1434 (unmetallized) 
Gas Permeability - O2, 24 hr  48  0.08  cc/100 in²  ASTM D1434 77℉/75% RH/1 ATM (metallized) 
WVTR  48  2.0  g/100 in²/day  ASTM F1249 38℃, 90% RH (unmetallized) 
WVTR  48  0.05  g/100 in²/day  ASTM F1249 38℃, 90% RH (metallized) 
WVTR  92  2.07  g/100 in²/day  ASTM F1249 38℃, 90% RH (unmetallized)  
 
OPTICAL
Haze  48  3.6  ASTM D1003 
Haze  92  ASTM D1003 
Total Light Transmission (TLT)  48  88.5  ASTM D1003 
 
PHYSICAL
C.O.F. (dynamic) A-B  48-92  0.4    ASTM D1894 
C.O.F. (static)  48-92  0.5    ASTM D1894 
Density  48-92  1.40  g/cc   
Elongation at Break MD  48-92  110  ASTM D882A 
Elongation at Break TD  48-92  70  ASTM D882A 
Tensile Strength MD  48-92  31  kpsi  ASTM D882A 
Tensile Strength TD  48  42  kpsi  ASTM D882A 
Tensile Strength TD  92  35  kpsi  ASTM D882A 
Yield (nominal)  48  42,200  in²/lb   
Yield (nominal)  92  21,500  in²/lb   
 
THERMAL
Shrinkage MD (190℃)  48-92  3.5  Unrestrained @ 190℃/5 min 
Shrinkage TD (190℃)  48-92  3.5  Unrestrained @ 190℃/5 min 



Contact Info
Mylar® Specialty Films U.S. Limited Partnership
3600 Discovery Drive
Chester, VA 23836-6436 USA
Tel: (800) 635-4639
Fax: (804) 530-9867



Disclaimer
Note: These values are typical performance data for Mylar® Specialty Films' polyester film; they are not intended to be used as design data. We believe this information is the best currently available on the subject. It is offered as a possible helpful suggestion in experimentation you may care to undertake along these lines. It is subject to revision as additional knowledge and experience is gained. Mylar® Specialty Films makes no guarantee of results and assumes no obligation or liability whatsoever in connection with this information. This publication is not a license to operate under, or intended to suggest infringement of, any existing patents.

CAUTION: Do not use in medical applications involving permanent implantation in the human body (Mylar® Specialty Films Medical Policy). For other medical applications, see the Medical Caution Statement. Mylar® Specialty Films accepts no liability for use of it's products in medical applications not reviewed and approved by Mylar® Specialty Films or for product misuse. Mylar® Specialty Films supplies products to an agreed specification and does not manufacture products designed specifically for medical end use.

Melinex®, Mylar® and Melinex® STTM are registered trademarks of Mylar® Specialty Films U.S. Limited Partnership.