MYLAR® 800C

Product Description
Mylar® 800C is a clear polyester film which is corona treated on one side. The corona treatment improves adhesion of inks and other substrates used in lamination.


Approvals
Food Contact Status - Please contact your Mylar® Specialty Films representative to receive the Regulatory Compliance documents


Typical Properties
Available Thickness [Gauge]
48;    75;    92


Property Thickness Value Units Test
BARRIER
Gas Permeability - O2, 24 hr  48  cc/100 in²  ASTM D1434 77℉/75% RH/1 ATM 
Gas Permeability - O2, 24 hr  75  cc/100 in²  ASTM D1434 77℉/75% RH/1 ATM 
WVTR  48  2.8  g/100 in²/day  ASTM F1249 38℃, 90% RH 
WVTR  75  1.8  g/100 in²/day  ASTM F1249 38℃, 90% RH 
 
OPTICAL
Haze  48  4.0  ASTM D1003 
Haze  75  5.5  ASTM D1003 
Haze  92  6.0  ASTM D1003 
Total Light Transmission (TLT)  48  89.0  ASTM D1003 
Total Light Transmission (TLT)  75  88.0  ASTM D1003 
 
PHYSICAL
C.O.F. (static) A-B  48 - 92  0.5    ASTM D1895 
Density  48 - 92  1.4  g/cc   
Elongation at Break MD  48 - 92  110  ASTM D822A 
Elongation at Break TD  48 - 92  90  ASTM D822A 
Surface Tension (Minimum)  48 - 92  50  Dyne/cm  ASTM D2578 
Tensile Strength MD  48 - 92  32,700  psi  ASTM D822A 
Tensile Strength TD  48 - 92  34,100  psi  ASTM D822A 
Yield (nominal)  48  42,200  in2/lb   
Yield (nominal)  75  26,600  in2/lb   
Yield (nominal)  92  21,565  in2/lb   
 
THERMAL
Shrinkage MD (150℃)  48 - 92  1.25  Unrestrained @ 150℃/30 min 
Shrinkage TD (150℃)  48 - 92  1.25  Unrestrained @ 150℃/30 min 


Contact Info
Mylar® Specialty Films U.S. Limited Partnership
3600 Discovery Drive
Chester, VA 23836-6436 USA
Tel: (800) 635-4639
Fax: (804) 530-9867


Disclaimer
Note: These values are typical performance data for Mylar® Specialty Films' polyester film; they are not intended to be used as design data. We believe this information is the best currently available on the subject. It is offered as a possible helpful suggestion in experimentation you may care to undertake along these lines. It is subject to revision as additional knowledge and experience is gained. Mylar® Specialty Films makes no guarantee of results and assumes no obligation or liability whatsoever in connection with this information. This publication is not a license to operate under, or intended to suggest infringement of, any existing patents.

CAUTION: Do not use in medical applications involving permanent implantation in the human body (Mylar® Specialty Films Medical Policy). For other medical applications, see the Medical Caution Statement. Mylar® Specialty Films accepts no liability for use of it's products in medical applications not reviewed and approved by Mylar® Specialty Films or for product misuse. Mylar® Specialty Films supplies products to an agreed specification and does not manufacture products designed specifically for medical end use.

Melinex®, Mylar® and Melinex® STTM are registered trademarks of Mylar® Specialty Films U.S. Limited Partnership.
 
  Show Printable Version
 
  Copyright © 2024 Mylar® Specialty Films. All rights reserved. | Privacy
  Developed and Powered by Client Centered Technologies, Inc.