Welcome, Guest Current Language:   US
  Home | Welcome Page | Film Type Selector | Market Locator | Product Locator
 

Show Printable Version  
 
MELINEX® 561

Product Description
Melinex® 561 is a high clarity polyester film which is pretreated on both sides to promote adhesion to many industrial coatings and inks. Melinex® 561 is suitable for applications which require a more die cuttable polyester film.

Approvals
UL Recognition - Product has been registered with Underwriters Laboratories


Typical Properties
Available Thickness [Gauge]
500;    700;    1000


Property Thickness Value Units Test
OPTICAL
Haze  1000  1.9  ASTM D1003 
Haze  500  0.4  ASTM D1003 
Haze  700  0.5  ASTM D1003 
Total Light Transmission (TLT)  1000  85.0  ASTM D1003 
Total Light Transmission (TLT)  500  88.0  ASTM D1003 
Total Light Transmission (TLT)  700  87.0  ASTM D1003 
 
PHYSICAL
C.O.F. (dynamic) A-B    0.5    ASTM D1894 
Elongation at Break MD    200  ASTM D882A 
Elongation at Break TD    120  ASTM D882A 
Tensile Strength MD    24,000  psi  ASTM D882A 
Tensile Strength TD    30,000  psi  ASTM D882A 
Yield Strength MD    14,000  psi  ASTM D882A 
Yield Strength TD    14,000  psi  ASTM D882A 
 
THERMAL
Shrinkage MD (190°C)    1.7  Unrestrained @ 190°C/5 min 
Shrinkage TD (190°C)    1.9  Unrestrained @ 190°C/5 min 


Contact Info
DuPont Teijin Films U.S. Limited Partnership
3600 Discovery Drive
Chester, VA 23836 USA
Tel: (800) 635-4639
Fax: (804) 530-9867


Disclaimer
Note: These values are typical performance data for DuPont Teijin Films' polyester film; they are not intended to be used as design data. We believe this information is the best currently available on the subject. It is offered as a possible helpful suggestion in experimentation you may care to undertake along these lines. It is subject to revision as additional knowledge and experience is gained. DuPont Teijin Films makes no guarantee of results and assumes no obligation or liability whatsoever in connection with this information. This publication is not a license to operate under, or intended to suggest infringement of, any existing patents.

CAUTION: Do not use in medical applications involving permanent implantation in the human body (DuPont Teijin Films Medical Policy). For other medical applications, see the Medical Caution Statement. DuPont Teijin Films accepts no liability for use of it's products in medical applications not reviewed and approved by DuPont Teijin Films or for product misuse. DuPont Teijin Films supplies products to an agreed specification and does not manufacture products designed specifically for medical end use.

Melinex®, Mylar® and Melinex® STTM are registered trademarks of DuPont Teijin Films U.S. Limited Partnership.
 
  Show Printable Version
 
  Copyright © 2006 DuPont Teijin Films. All rights reserved. | Privacy
  Developed and Powered by Client Centered Technologies, Inc.