A high clarity film which is two side pretreated for slip to combine good handling properties with high clarity and brilliance.
|
MELINEX® 515 is suitable for applications which require a more die cuttable polyester film.
|
UL Recognition -
Product has been registered with Underwriters Laboratories.
Library of Congress Specification -
This film meets the Library of Congress Specification Number 500-500-5/31/95 for use in archival storage.
|
Available Thickness [Gauge] |
650; 700; 1000
|
|
|
Property |
Thickness |
Value |
Units |
Test |
OPTICAL
|
Haze |
1000 |
1.0 |
% |
ASTM D1003 |
Total Light Transmission (TLT) |
1000 |
85.5 |
% |
ASTM D1003 |
Total Light Transmission (TLT) |
650 |
87.0 |
% |
ASTM D1003 |
|
PHYSICAL
|
C.O.F. (dynamic) A-B |
|
0.5 |
|
ASTM D1894 |
Density |
650 - 1000 |
1.40 |
g/cm3 |
|
Elongation at Break MD |
|
190 |
% |
ASTM D882A |
Elongation at Break TD |
|
120 |
% |
ASTM D882A |
Tensile Strength MD |
|
25,000 |
psi |
ASTM D882A |
Tensile Strength TD |
|
29,000 |
psi |
ASTM D882A |
Yield (nominal) |
700 |
2,840 |
in²/lb |
|
Yield Strength MD |
|
14,500 |
psi |
ASTM D882A |
Yield Strength TD |
|
14,500 |
psi |
ASTM D882A |
|
THERMAL
|
Shrinkage MD (190℃) |
|
2.5 |
% |
Unrestrained @ 190℃/5 min |
Shrinkage TD (190℃) |
|
1.0 |
% |
Unrestrained @ 190℃/5 min |
|
|
Mylar® Specialty Films U.S. Limited Partnership
3600 Discovery Drive
Chester, VA 23836-6436 USA
Tel: (800) 635-4639
Fax: (804) 530-9867
|
Note: These values are typical performance data for Mylar® Specialty Films' polyester film; they are not intended to be used as design data. We believe this information is the best currently available on the subject. It is offered as a possible helpful suggestion in experimentation you may care to undertake along these lines. It is subject to revision as additional knowledge and experience is gained. Mylar® Specialty Films makes no guarantee of results and assumes no obligation or liability whatsoever in connection with this information. This publication is not a license to operate under, or intended to suggest infringement of, any existing patents.
CAUTION: Do not use in medical applications involving permanent implantation in the human body (Mylar® Specialty Films Medical Policy). For other medical applications, see the Medical Caution Statement. Mylar® Specialty Films accepts no liability for use of it's products in medical applications not reviewed and approved by Mylar® Specialty Films or for product misuse. Mylar® Specialty Films supplies products to an agreed specification and does not manufacture products designed specifically for medical end use.
Melinex®, Mylar® and Melinex® STTM are registered trademarks of Mylar® Specialty Films U.S. Limited Partnership.
|
|