MELINEX® 515

Product Description
A high clarity film which is two side pretreated for slip to combine good handling properties with high clarity and brilliance.


Typical Applications
MELINEX® 515 is suitable for applications which require a more die cuttable polyester film.


Approvals
UL Recognition - Product has been registered with Underwriters Laboratories.
Library of Congress Specification - This film meets the Library of Congress Specification Number 500-500-5/31/95 for use in archival storage.



Typical Properties
Available Thickness [Gauge]
650;    700;    1000


Property Thickness Value Units Test
OPTICAL
Haze  1000  1.0  ASTM D1003 
Total Light Transmission (TLT)  1000  85.5  ASTM D1003 
Total Light Transmission (TLT)  650  87.0  ASTM D1003 
 
PHYSICAL
C.O.F. (dynamic) A-B    0.5    ASTM D1894 
Density  650 - 1000  1.40  g/cm3   
Elongation at Break MD    190  ASTM D882A 
Elongation at Break TD    120  ASTM D882A 
Tensile Strength MD    25,000  psi  ASTM D882A 
Tensile Strength TD    29,000  psi  ASTM D882A 
Yield (nominal)  700  2,840  in²/lb   
Yield Strength MD    14,500  psi  ASTM D882A 
Yield Strength TD    14,500  psi  ASTM D882A 
 
THERMAL
Shrinkage MD (190℃)    2.5  Unrestrained @ 190℃/5 min 
Shrinkage TD (190℃)    1.0  Unrestrained @ 190℃/5 min 



Contact Info
Mylar® Specialty Films U.S. Limited Partnership
3600 Discovery Drive
Chester, VA 23836-6436 USA
Tel: (800) 635-4639
Fax: (804) 530-9867



Disclaimer
Note: These values are typical performance data for Mylar® Specialty Films' polyester film; they are not intended to be used as design data. We believe this information is the best currently available on the subject. It is offered as a possible helpful suggestion in experimentation you may care to undertake along these lines. It is subject to revision as additional knowledge and experience is gained. Mylar® Specialty Films makes no guarantee of results and assumes no obligation or liability whatsoever in connection with this information. This publication is not a license to operate under, or intended to suggest infringement of, any existing patents.

CAUTION: Do not use in medical applications involving permanent implantation in the human body (Mylar® Specialty Films Medical Policy). For other medical applications, see the Medical Caution Statement. Mylar® Specialty Films accepts no liability for use of it's products in medical applications not reviewed and approved by Mylar® Specialty Films or for product misuse. Mylar® Specialty Films supplies products to an agreed specification and does not manufacture products designed specifically for medical end use.

Melinex®, Mylar® and Melinex® STTM are registered trademarks of Mylar® Specialty Films U.S. Limited Partnership.