MELINEX® 475 is a high yield, translucent polyester film with superb handling properties. Both surfaces are pretreated to promote adhesion to most industrial coatings. The side with the lower gloss (Side A) is wound on the outside.
|
This film has low extractables and a high tear strength
|
UL Recognition -
Product has been registered with Underwriters Laboratories
|
Available Thickness [Gauge] |
200
|
|
|
Property |
Thickness |
Value |
Units |
Test |
ELECTRICAL
|
Surface Resistivity |
|
10^15 |
Ohms/sq |
ASTM D257 (500 V DC @ 25℃ 50% RH) |
Volume Resistivity |
|
10^17 |
Ohms-cm |
ASTM D257 (100 V DC 25℃, 50% RH, 1000 sec electrification time) |
|
OPTICAL
|
Gloss 60 Degrees |
200 |
65 |
|
ASTM D1003 (A side) |
Gloss 60 Degrees |
200 |
110 |
|
ASTM D1003 (B side) |
Total Light Transmission (TLT) |
200 |
50 |
% |
ASTM D1003 |
|
PHYSICAL
|
C.O.F. (dynamic) A-B |
200 |
0.3 |
|
ASTM D1894 |
Density |
|
1.25 |
g/cc |
ASTM D1505 |
Elongation at Break MD |
200 |
160 |
% |
ASTM D882A |
Elongation at Break TD |
200 |
105 |
% |
ASTM D882A |
Tensile Strength MD (break) |
200 |
25,600 |
psi |
ASTM D882A |
Tensile Strength MD 5% |
200 |
12,000 |
psi |
ASTM D882A |
Tensile Strength TD (break) |
200 |
29,250 |
psi |
ASTM D882A |
Tensile Strength TD 5% |
200 |
11,600 |
psi |
ASTM D882A |
|
THERMAL
|
Shrinkage MD (190℃) |
200 |
3.0 |
% |
Unrestrained @ 190℃/5 min |
Shrinkage TD (190℃) |
200 |
0.5 |
% |
Unrestrained @ 190℃/5 min |
|
|
Mylar® Specialty Films U.S. Limited Partnership
3600 Discovery Drive
Chester, VA 23836-6436 USA
Tel: (800) 635-4639
Fax: (804) 530-9867
|
Note: These values are typical performance data for Mylar® Specialty Films' polyester film; they are not intended to be used as design data. We believe this information is the best currently available on the subject. It is offered as a possible helpful suggestion in experimentation you may care to undertake along these lines. It is subject to revision as additional knowledge and experience is gained. Mylar® Specialty Films makes no guarantee of results and assumes no obligation or liability whatsoever in connection with this information. This publication is not a license to operate under, or intended to suggest infringement of, any existing patents.
CAUTION: Do not use in medical applications involving permanent implantation in the human body (Mylar® Specialty Films Medical Policy). For other medical applications, see the Medical Caution Statement. Mylar® Specialty Films accepts no liability for use of it's products in medical applications not reviewed and approved by Mylar® Specialty Films or for product misuse. Mylar® Specialty Films supplies products to an agreed specification and does not manufacture products designed specifically for medical end use.
Melinex®, Mylar® and Melinex® STTM are registered trademarks of Mylar® Specialty Films U.S. Limited Partnership.
|
|